2 Parameters
2.3 Parameters for data sets
SINAMICS G120D
566
List Manual (LH14), 01/2016, A5E33842313
p1463[0...n]
Speed controller Tn adaptation speed upper scaling / n_ctr Tn n up scal
p1464[0...n]
Speed controller adaptation speed lower / n_ctrl n lower
p1465[0...n]
Speed controller adaptation speed upper / n_ctrl n upper
p1470[0...n]
Speed controller encoderless operation P-gain / n_ctrl SL Kp
p1472[0...n]
Speed controller encoderless operation integral time / n_ctrl SL Tn
p1487[0...n]
Droop compensation torque scaling / Droop M_comp scal
p1488[0...n]
Droop input source / Droop input source
p1489[0...n]
Droop feedback scaling / Droop scal
p1496[0...n]
Acceleration pre-control scaling / a_prectrl scal
p1498[0...n]
Load moment of inertia / Load M_inertia
p1499[0...n]
Accelerating for torque control scaling / a for M_ctrl scal
p1514[0...n]
Supplementary torque 2 scaling / M_suppl 2 scal
p1517[0...n]
Accelerating torque smoothing time constant / M_accel T_smooth
p1520[0...n]
CO: Torque limit upper / M_max upper
p1521[0...n]
CO: Torque limit lower / M_max lower
p1524[0...n]
CO: Torque limit upper scaling / M_max upper scal
p1525[0...n]
CO: Torque limit lower scaling / M_max lower scal
p1530[0...n]
Power limit motoring / P_max mot
p1531[0...n]
Power limit regenerative / P_max gen
p1553[0...n]
Stall limit scaling / Stall limit scal
p1560[0...n]
Moment of inertia estimator accelerating torque threshold value / J_est M thresh
p1561[0...n]
Moment of inertia estimator change time moment of inertia / J_est t J
p1562[0...n]
Moment of inertia estimator change time load / J_est t load
p1563[0...n]
CO: Mom. of inertia estimator load torque direction of rotation pos. / J_est M pos
p1564[0...n]
CO: Mom. of inertia estimator load torque direction of rotation neg. / J_est M neg
p1570[0...n]
CO: Flux setpoint / Flex setp
p1573[0...n]
Flux threshold value magnetizing / Flux thresh magnet
p1574[0...n]
Voltage reserve dynamic / U_reserve dyn
p1575[0...n]
Voltage target value limit / U_tgt val lim
p1580[0...n]
Efficiency optimization / Efficiency opt.
p1582[0...n]
Flux setpoint smoothing time / Flux setp T_smth
p1584[0...n]
Field weakening operation flux setpoint smoothing time / Field weak T_smth
p1586[0...n]
Field weakening characteristic scaling / Field weak scal
p1590[0...n]
Flux controller P gain / Flux controller Kp
p1594[0...n]
Field-weakening controller P gain / Field_ctrl Kp
p1595[0...n]
Field weakening controller additional setpoint / Field_ctr add_setp
p1596[0...n]
Field weakening controller integral-action time / Field_ctrl Tn
p1610[0...n]
Torque setpoint static (sensorless) / M_set static
p1611[0...n]
Additional acceleration torque (sensorless) / M_suppl_accel
p1616[0...n]
Current setpoint smoothing time / I_set T_smooth
p1654[0...n]
Curr. setpoint torque-gen. smoothing time field weakening range / Isq_s T_smth FW
p1702[0...n]
Isd current controller pre-control scaling / Isd_ctr_prectrScal
p1703[0...n]
Isq current controller pre-control scaling / Isq_ctr_prectrScal
p1715[0...n]
Current controller P gain / I_ctrl Kp
p1717[0...n]
Current controller integral-action time / I_ctrl Tn
p1726[0...n]
Quadrature arm decoupling scaling / Transv_decpl scal
p1727[0...n]
Quadrature arm decoupling at voltage limit scaling / TrnsvDecplVmaxScal
p1730[0...n]
Isd controller integral component shutdown threshold / Isd ctrl Tn shutd
p1731[0...n]
Isd controller combination current time component / Isd ctr I_combi T1
p1740[0...n]
Gain resonance damping for encoderless closed-loop control / Gain res_damp
p1744[0...n]
Motor model speed threshold stall detection / MotMod n_thr stall
p1745[0...n]
Motor model error threshold stall detection / MotMod ThreshStall
p1749[0...n]
Motor model increase changeover speed encoderless operation / Incr n_chng no enc
p1750[0...n]
Motor model configuration / MotMod config
p1752[0...n]
Motor model changeover speed operation with encoder / MotMod n_chgov enc