2 Parameters
2.2 List of parameters
SINAMICS G120D
46
List Manual (LH14), 01/2016, A5E33842313
Description:
Display and connector output for actual torque value.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: r0031, p0045
Note:
The value is available smoothed (r0031 with 100 ms, r0080[1] with p0045) and unsmoothed (r0080[0]).
Description:
Displays the torque utilization as a percentage.
The torque utilization is obtained from the required smoothed torque referred to the torque limit.
Dependency:
This parameter is only available for vector control. For U/f control r0081 = 0 %.
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Refer to: r0033
Note:
The torque utilization is available smoothed (r0033) and unsmoothed (r0081).
The torque utilization is obtained from the required torque referred to the torque limit as follows:
- Positive torque: r0081 = (r0079 / r1538) * 100 %
- Negative torque: r0081 = (-r0079 / -r1539) * 100 %
Description:
Displays the instantaneous active power.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
[2] = Electric power
Dependency:
Refer to: r0032
Note:
The mechanical active power is available smoothed (r0032 with 100 ms, r0082[1] with p0045) and unsmoothed
(r0082[0]).
Description:
Displays the flux setpoint.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r0080[0...1]
CO: Torque actual value / M_act
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2003
Dyn. index:
-
Unit group:
7_1
Unit selection:
p0505
Func. diagram:
6714, 6799
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
r0081
CO: Torque utilization / M_Utilization
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
8012
Min Max
Factory
setting
- [%]
- [%]
- [%]
r0082[0...2]
CO: Active power actual value / P_act
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
r2004
Dyn. index:
-
Unit group:
14_5
Unit selection:
p0505
Func. diagram:
6714, 6799
Min Max
Factory
setting
- [kW]
- [kW]
- [kW]
r0083
CO: Flux setpoint / Flex setp
Access level:
4
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
5722
Min Max
Factory
setting
- [%]
- [%]
- [%]