SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
519
2 Parameters
2.2 List of parameters
Description:
Setting parameter for the run-time group in which the instance PCL 0 of the pulse shortener is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance PCL 0 within the run-time group set in p20151.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source for the input pulse I of instance PCL 1 of the pulse shortener.
Description:
Setting parameter for pulse duration T in milliseconds of instance PCL 1 of the pulse shortener.
Description:
Display parameter for output pulse Q of instance PCL 1 of the pulse shortener.
Description:
Setting parameter for the run-time group in which the instance PCL 1 of the pulse shortener is to be called.
p20151
PCL 0 run-time group / PCL 0 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
5 9999
9999
p20152
PCL 0 run sequence / PCL 0 RunSeq
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
0 32000
400
p20153
BI: PCL 1 input pulse I / PCL 1 inp_pulse I
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
- - 0
p20154
PCL 1 pulse duration in ms / PCL 1 pulse_dur ms
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
0.00 5400000.00
0.00
r20155
BO: PCL 1 output Q / PCL 1 output Q
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
- - -
p20156
PCL 1 run-time group / PCL 1 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
5 9999
9999