2 Parameters
2.2 List of parameters
SINAMICS G120D
342
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the signal source for the adaptation of the proportional gain of the position controller.
Dependency:
Refer to: p2538
Description:
Sets the proportional gain (P gain, position loop gain, Kv factor) of the position controller.
Dependency:
Refer to: p2537, p2539, p2555, r2557, r2558
Note:
The proportional gain is used define at which traversing velocity which following error is obtained (without pre-control)
Low proportional gain:
Slow response to a setpoint - actual value difference, the following error becomes large.
High proportional gain:
Fast response to the setpoint - actual value difference, the following error becomes small.
Description:
Setting to activate the integral time of the position controller.
Value = 0 ms --> The I component of the position controller is de-activated.
Dependency:
Refer to: p2538, r2559, p2731
Notice:
The effectiveness of the I component corresponding to the set integral time depends on binector input p2731.
Description:
Setting and connector output for the speed limit of the position controller output.
Dependency:
Refer to: p2541
Description:
Sets the signal source for the position controller output limit.
Dependency:
Refer to: p2540
p2537
CI: LR position controller adaptation / Adaptation
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- - 1
p2538[0...n]
LR proportional gain / Kp
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
0.000 [1000 rpm]
300.000 [1000 rpm]
1.000 [1000 rpm]
p2539[0...n]
LR integral time / Tn
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
DDS, p0180
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
0.00 [ms]
100000.00 [ms]
0.00 [ms]
p2540
CO: LR position controller output speed limit / LR_outp n_lim
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
4015
Min Max
Factory
setting
0.000 [rpm]
210000.000 [rpm]
210000.000 [rpm]
p2541
CI: LR position controller output speed limit signal source / LR_out n_lim S_src
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
p2000
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4015
Min Max
Factory
setting
- - 2540[0]