SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
153
2 Parameters
2.2 List of parameters
17:
Motor potenti analog setpoint 2
20:
Analog se no main setpoint
21:
Analog se motor potentiometer
22:
Analog se analog setpoint
23:
Analog se fixed speed setpoint
26:
Analog se fieldbus
27:
Analog se analog setpoint 2
30:
Fixed speed se no main setpoint
31:
Fixed speed se motor potentiometer
32:
Fixed speed se analog setpoint
33:
Fixed speed se fixed speed setpoint
36:
Fixed speed se fieldbus
37:
Fixed speed se analog setpoint 2
60:
Fi no main setpoint
61:
Fi motor potentiometer
62:
Fi analog setpoint
63:
Fi fixed speed setpoint
66:
Ffieldbus
67:
Fi analog setpoint 2
70:
Analog setpoint 2 + no main setpoint
71:
Analog setpoint 2 + motor potentiometer
72:
Analog setpoint 2 + analog setpoint
73:
Analog setpoint 2 + fixed speed setpoint
76:
Analog setpoint 2 + fieldbus
77:
Analog setpoint 2 + analog setpoint 2
Dependency:
When changing this parameter, the following settings are influenced:
Refer to: p1070, p1071, p1075, p1076
Caution:
If p1000 is selected as the main setpoint of the fieldbus, the following BICO interconnection is set automatically:
p2051[1] = r0063
Notice:
The parameter is possibly protected as a result of p0922.
For PROFIBUS/PROFINET Control Units, the following applies: The parameter can be freely set by setting p0922 =
999.
When executing a specific macro, the corresponding programmed settings are made and become active.
Description:
Sets the source for the speed setpoint.
For single-digit values, the following applies:
The value specifies the main setpoint.
For double-digit values, the following applies:
The left-hand digit specifies the supplementary setpoint, the right-hand digit the main setpoint.
Example:
Value = 26
--> The analog setpoint (2) supplies the supplementary setpoint.
--> The fieldbus (6) supplies the main setpoint.
Value:
0:
No main setpoint
1:
Motorized potentiometer
3:
Fixed speed setpoint
6:
Fieldbus
10:
Motor potenti no main setpoint
11:
Motor potenti motor potentiometer
13:
Motor potenti fixed speed setpoint
16:
Motor potenti fieldbus
30:
Fixed speed se no main setpoint
31:
Fixed speed se motor potentiometer
33:
Fixed speed se fixed speed setpoint
p1000[0...n]
Speed setpoint selection / n_set sel
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
1
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
CDS, p0170
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 66
0