SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
547
2 Parameters
2.2 List of parameters
Description:
Sets the signal source of input quantities X0 and X1 of instance NCM 0 of the numeric comparator.
Index:
[0] = Input X0
[1] = Input X1
Description:
Display parameter for binary quantity QU of instance NCM 0 of the numeric comparator.
QU is only set if X0 > X1.
Description:
Display parameter for binary quantity QE of instance NCM 0 of the numeric comparator.
QE is only set if X0 = X1.
Description:
Display parameter for binary quantity QL of instance NCM 0 of the numeric comparator.
QL is only set if X0 < X1.
Description:
Setting parameter for the run-time group in which the instance NCM 0 of the numeric comparator is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
p20312[0...1]
CI: NCM 0 inputs / NCM 0 inputs
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7225
Min Max
Factory
setting
- - 0
r20313
BO: NCM 0 output QU / NCM 0 output QU
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7225
Min Max
Factory
setting
- - -
r20314
BO: NCM 0 output QE / NCM 0 output QE
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7225
Min Max
Factory
setting
- - -
r20315
BO: NCM 0 output QL / NCM 0 output QL
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7225
Min Max
Factory
setting
- - -
p20316
NCM 0 run-time group / NCM 0 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7225
Min Max
Factory
setting
5 9999
9999