2 Parameters
2.2 List of parameters
SINAMICS G120D
50
List Manual (LH14), 01/2016, A5E33842313
Description:
Displays the BIOS and EEPROM data version.
r0198[0]: BIOS version
r0198[1]: EEPROM data version EEPROM 0
r0198[2]: EEPROM data version EEPROM 1
Dependency:
Refer to: r0018, r0197
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description:
Displays the unique code number of the power unit.
Note:
r0200 = 0: No power unit data found
Description:
Sets the actual code number from r0200 to acknowledge the power unit being used.
When commissioned for the first time, the code number is automatically transferred from r0200 into p0201.
Note:
The parameter is used to identify when the drive is being commissioned for the first time.
The power unit commissioning can only be exited (p0201 = r0200), if the actual and acknowledged code numbers are
identical (p0010 = 2).
When the code number is changed, the connection voltage (p0210) is checked and, if necessary, adjusted.
Description:
Displays the type of power unit found.
Value:
2:
MICROMASTER 440
3:
MICROMASTER 411
4:
MICROMASTER 410
5:
MICROMASTER 436
6:
MICROMASTER 440 PX
7:
MICROMASTER 430
100:
SINAMICS S
101:
SINAMICS S (value)
102:
SINAMICS S (combi)
103:
SINAMICS S120M (distributed)
112:
PM220 (SINAMICS G120)
r0198[0...2]
BIOS/EEPROM data version / BIOS/EEPROM vers
Access level:
4
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r0200[0...n]
Power unit code number actual / PU code no. act
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
PDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p0201[0...n]
Power unit code number / PU code no
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
C(2)
Scaling:
-
Dyn. index:
PDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 65535
0
r0203[0...n]
Actual power unit type / PU actual type
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
-
Scaling:
-
Dyn. index:
PDS
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
2 400
-