2 Parameters
2.2 List of parameters
SINAMICS G120D
148
List Manual (LH14), 01/2016, A5E33842313
Description:
Displays the PROFIdrive profile number and profile version.
Constant value = 0329 hex.
Byte 1: Profile number = 03 hex = PROFIdrive profile
Byte 2: Profile version = 29 hex = Version 4.1
Note:
When the parameter is read via PROFIdrive, the Octet String 2 data type applies.
Description:
Displays the system runtime in ms since the last POWER ON.
Note:
The value in p0969 can only be reset to 0.
The value overflows after approx. 49 days.
When the parameter is read via PROFIdrive, the TimeDifference data type applies.
Description:
The parameter is used to initiate the reset of the drive parameters.
Parameters p0100, p0205 are not reset.
The following motor parameters are defined in accordance with the power unit: p0300 ... p0311.
When downloading settings 10, 11, 12, the buffer memory mode is automatically de-activated (p0014 = 0).
Value:
0:
Inactive
1:
Start a parameter reset
3:
Start download of volatile parameters from RAM
5:
Starts a safety parameter reset
10:
Start loading the parameters saved with p0971=10
11:
Start loading the parameters saved with p0971=11
12:
Start loading the parameters saved with p0971=12
30:
Start loading the delivery state saved with p0971=30
100:
Start a BICO interconnection reset
300:
Only Siemens int
Dependency:
Refer to: F01659
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
When the buffer memory is active (see p0014), the actual parameters are backed up from RAM to ROM when a
parameter set is loaded (p0970 = 10, 11, 12).
Peculiarities of communication via PROFIBUS DP:
- Communication with Class 1 masters (e.g. S7 controllers) is interrupted.
- Communication with Class 2 masters (e.g. STARTER) is retained.
r0965
PROFIdrive profile number / PD profile number
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p0969
System runtime relative / t_System relative
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
8050, 8060
Min Max
Factory
setting
0 [ms]
4294967295 [ms]
0 [ms]
p0970
Reset drive parameters / Drive par reset
Access level:
1
Calculated:
-
Data type:
Unsigned16
Can be changed:
C(1, 30)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 300
0