SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
437
2 Parameters
2.2 List of parameters
Description:
Sets the limit values for the function "Safely Limited Speed" (SLS).
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency:
Refer to: p9363, p9531
Refer to: C01714
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
SLS: Safely Limited Speed
Description:
Sets the tolerance for the crosswise data comparison of the actual position between processors 1 and 2.
Dependency:
Refer to: p9542
Refer to: C01711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
For a linear axis, the tolerance is internally limited to 10 mm.
For a "linear axis with rotating motor" and factory setting of p9320, p9321 and p9322, the factory setting of p9342
corresponds to a position tolerance of 36 ° on the motor side.
Description:
Sets the tolerance for checking the actual values.
For an incremental encoder, the actual values are checked after referencing; for an absolute encoder, when
switching on.
Dependency:
Refer to: C01711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
For linear axes, the maximum value is limited to 1 mm.
Description:
Sets the filter time for the SSM feedback signal to detect standstill.
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
p9331[0...3]
SI Motion SLS limit values (processor 2) / SI Mtn SLS lim P2
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.01 [rpm]
100000.00 [rpm]
2000.00 [rpm]
p9342
SI Motion act. val. comparison tolerance (crossw.) (processor 2) / SI Mtn actV tol P2
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.0010 [°]
360.0000 [°]
12.0000 [°]
p9344
SI Motion actual value comparison tolerance (referencing) (MM) / SI mtn ref tol MM
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.0000 [mm]
36.0000 [mm]
0.0100 [mm]
p9345
SI Motion SSM filter time (processor 2) / SI Mtn SSM filt P2
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2823
Min Max
Factory
setting
0.00 [µs]
100000.00 [µs]
0.00 [µs]