2 Parameters
2.2 List of parameters
Description:
Display and connector output for the field-generating current setpoint (Id_set).
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
This value is irrelevant for the U/f control mode.
Description:
Display and connector output for the field-generating current actual value (Id_act).
Dependency:
Refer to: r0029
Note:
This value is irrelevant for the U/f control mode.
The field-generating current actual value is available smoothed (r0029) and unsmoothed (r0076).
Description:
Display and connector output for the torque-generating current setpoint.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note:
This value is irrelevant for the U/f control mode.
Description:
Display and connector output for the torque-generating current actual value (Iq_act).
Dependency:
Refer to: r0030
Note:
This value is irrelevant for the U/f control mode.
The torque-generating current actual value is available smoothed (r0030 with 300 ms) and unsmoothed (r0078).
Description:
Display and connector output for the torque setpoint at the output of the speed controller.
Dependency:
Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
r0075
CO: Current setpoint field-generating / Id_set
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2002
Dyn. index:
-
Unit group:
6_2
Unit selection:
p0505
Func. diagram:
6700, 6714, 6725
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r0076
CO: Current actual value field-generating / Id_act
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2002
Dyn. index:
-
Unit group:
6_2
Unit selection:
p0505
Func. diagram:
5700, 5714, 5730,
6700, 6714, 6799
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r0077
CO: Current setpoint torque-generating / Iq_set
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2002
Dyn. index:
-
Unit group:
6_2
Unit selection:
p0505
Func. diagram:
6700, 6710
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r0078
CO: Current actual value torque-generating / Iq_act
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2002
Dyn. index:
-
Unit group:
6_2
Unit selection:
p0505
Func. diagram:
6310, 6700, 6714,
6799
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r0079
CO: Torque setpoint / M_set
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2003
Dyn. index:
-
Unit group:
7_1
Unit selection:
p0505
Func. diagram:
6020, 6060, 6710
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]