![Siemens SINAMICS G120D CU240D-2 DP Manual Download Page 106](http://html.mh-extra.com/html/siemens/sinamics-g120d-cu240d-2-dp/sinamics-g120d-cu240d-2-dp_manual_381563106.webp)
2 Parameters
2.2 List of parameters
SINAMICS G120D
106
List Manual (LH14), 01/2016, A5E33842313
Description:
Sets the edge to evaluate the measuring probe signal for speed actual value measurement.
0: 0/1 edge
1: 1/0 edge
Dependency:
Refer to: p0580
Description:
Sets the number of pulses per revolution (e.g. for disks with holes).
Description:
Sets the maximum measuring time for the measuring probe.
If a new pulse is not received before the maximum measuring time has expired, then the speed actual value in r0586
is set to zero. This timer is re-started with the next pulse.
Dependency:
Refer to: r0586
Description:
Sets the BERO gear factor.
The measured speed is multiplied by the BERO gear factor and is displayed in r0586.
Description:
Displays the speed actual value measured using the BERO.
Dependency:
Refer to: p0580, p0583
Note:
For p0580 = 0 (no measuring probe), a value of zero is displayed here.
p0581
Measuring probe edge / MT edge
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 1 0
p0582
Measuring probe pulses per revolution / MT pulses per rev
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
1 12
1
p0583
Measuring probe maximum measuring time / MT t_meas max
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.040 [s]
10.000 [s]
10.000 [s]
p0585
Measuring probe gear factor / Probe gear factor
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0.00000 1000.00000
1.00000
r0586
CO: Measuring probe speed actual value / MT n_act
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
p2000
Dyn. index:
-
Unit group:
3_1
Unit selection:
p0505
Func. diagram:
-
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]