![Siemens SINAMICS G120D CU240D-2 DP Manual Download Page 684](http://html.mh-extra.com/html/siemens/sinamics-g120d-cu240d-2-dp/sinamics-g120d-cu240d-2-dp_manual_381563684.webp)
3
F
unction
d
iag
ram
s
3.1
1
Se
tp
oint chan
nel
SINAMICS
G120D
68
4
L
ist Manual (LH
14)
, 01/2
016
, A5E3384231
3
F
ig.
3
-77
30
01 – Overvie
w
- 3001 -
Function diagram
8
7
6
5
4
3
2
1
fp_3001_97_53.vsd
Setpoint channel
SINAMICS G120D
09.12.2015
V4.7.6
Overview
+
+
+ / -
+
–
p1076
p1071
pos
neg
(-1)
1
0
+
+
+
Main setpoint
(2050[1])
p1070 [C]
Suppl setp
(0)
p1075 [C]
r1024
n_set_fixed eff [rpm]
Jog 1 n_set
-210000.000 ... 210000.000 [rpm]
p1058 [D] (150.000)
Jog 2 n_set
-210000.000 ... 210000.000 [rpm]
p1059 [D] (-150.000)
raise
Main/supplementary setpoint, setpoint
scaling, jogging
r1050
Mop setp after RFG [rpm]
Motorized potentiometer
Fixed speed setpoints
Extended ramp-function
generator
Basic ramp-function
generator
n_set_1
n_set_4
n_set_5
Simulate ramp-function generator
Ramp-function generator selection,
status word, tracking
Direction of rotating
limiting/changeover
Skip (suppression)
bandwidth and speed limiting
Ramp-function
generator
tracking
STW seq_ctrl
r0898
r0898
STW seq_ctrl
r0898
r0898
.9
RFG selection
0 ... 1
p1115 (0)
r1150
RFG n_set at outp [rpm]
n_act
M_limit
n_ctrl n_set 1
(0)
p1155 [C]
RFG ZSW
r1199
r1199
n_ctrl n_set 2
(0)
p1160 [C]
r1438
n_ctrl n_set [rpm]
lower
[3010], [3011]
[3040]
[3050]
[3070]
[3060]
[3080]
[3020]
r1114
Setp after limit
[rpm]
r1170
n_ctrl setp sum
[rpm]
.8
[3030]
1 0
0 1
0 0
1 1
ZSW
[6300.1]
[6020.1]
[8005.5]
r1119
RFG setp at inp
[rpm]