2 Parameters
2.2 List of parameters
SINAMICS G120D
282
List Manual (LH14), 01/2016, A5E33842313
[7] = Bit 7
[8] = Bit 8
[9] = Bit 9
[10] = Bit 10
[11] = Bit 11
[12] = Bit 12
[13] = Bit 13
[14] = Bit 14
[15] = Bit 15
Dependency:
Refer to: p2088, r2089
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description:
Selects bits to be sent to the PROFIdrive controller.
The individual bits are combined to form status word 2.
Index:
[0] = Bit 0
[1] = Bit 1
[2] = Bit 2
[3] = Bit 3
[4] = Bit 4
[5] = Bit 5
[6] = Bit 6
[7] = Bit 7
[8] = Bit 8
[9] = Bit 9
[10] = Bit 10
[11] = Bit 11
[12] = Bit 12
[13] = Bit 13
[14] = Bit 14
[15] = Bit 15
Dependency:
Refer to: p2088, r2089
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
For clock synchronous operation, bit 12 to 15 to transfer the sign-of-life are reserved in status word 2 - and may not
be freely interconnected.
Description:
Selects bits to be sent to the PROFIdrive controller.
The individual bits are combined to form free status word 3.
Index:
[0] = Bit 0
[1] = Bit 1
[2] = Bit 2
[3] = Bit 3
[4] = Bit 4
[5] = Bit 5
[6] = Bit 6
[7] = Bit 7
[8] = Bit 8
[9] = Bit 9
[10] = Bit 10
p2081[0...15]
BI: Binector-connector converter status word 2 / Bin/con ZSW2
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2472
Min Max
Factory
setting
- - 0
p2082[0...15]
BI: Binector-connector converter status word 3 / Bin/con ZSW3
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2472
Min Max
Factory
setting
- - 0