Page 1: ...Operator s manual Frequency converters FUH Machine Type FUH35 FUH70 Material number 5100056242 Version 4 0 Date 09 2020 Language en 5100056242...

Page 2: ...from the manufacturer Reproduction or translation of this publication in whole or part is not permitted without the written consent of Wacker Neuson Produktion GmbH Co KG Violations of legal regulati...

Page 3: ...nges 12 4 4 Responsibility of the operator 12 4 5 Obligations of the operator 13 4 6 Qualification of staff 13 4 7 General safety instructions 13 4 8 Specific safety instructions when operating electr...

Page 4: ...242 09 2020 en 10 1 Troubleshooting 25 11 Storage 11 1 Machine 28 11 2 Accumulator 28 12 Decommissioning 12 1 Final shutdown 29 13 Technical Data 13 1 General instructions 30 13 2 Noise information 30...

Page 5: ...of the manufacturer Product FUH35 FUH70 Product type Converter Function of product Conversion of voltage and frequency Material number 5100047262 5100047263 5100047264 5100047265 2014 35 EU 2014 30 E...

Page 6: ...ation or maintenance 2 2 Storage location of the operator s manual This operator s manual must be kept in the immediate vicinity of the ma chine and accessible to personnel at all times If this operat...

Page 7: ...to page 52 Explanation of symbols Symbol for warning notices This symbol is a warning symbol It is used to alert you to potential hazards The safety symbol is always followed by a signal word which i...

Page 8: ...f the following infringements the manufacturer disclaims any liability for personal injury and damage to property Actions contrary to this operator s manual Non designated use Deployment of untrained...

Page 9: ...is reason some illustrations may differ from the appearance of the pur chased machine Variant dependent components that are not in cluded in the scope of delivery can also be described Wacker Neuson r...

Page 10: ...acturer shall not be liable or liable for any damage resulting therefrom The risk is borne solely by the operator 3 2 Unintended use The manufacturer is not liable for personal injury or damage to pro...

Page 11: ...t can cause injury if it is not avoided Consequences in case of non observance Avoidance of injury NOTICE INFORMATION identifies a situation that causes damage if it is not observed Consequences in ca...

Page 12: ...moved safely Further information is available on the Internet at http www wackerneuson com 4 4 Responsibility of the operator The operator is the person who operates this machine himself for com merc...

Page 13: ...rovide personnel with the necessary protective equipment 4 6 Qualification of staff This machine may only be put into operation and operated by trained per sonnel In the event of misuse abuse or opera...

Page 14: ...fluence of drugs alcohol or medication can lead to serious injuries Suitable protective equipment must be worn for all work Personal protective equipment considerably reduces the risk of injury Keep w...

Page 15: ...at is inaccessible to other persons and children 4 8 Specific safety instructions when operating electrical appliances Information The rated voltage can be found on the type label of the machine Power...

Page 16: ...lent version Immediately replace damaged extension cables e g cracks in the sheath or loose plugs and couplings Cable drums and multiple plug receptacles must meet the same re quirements as extension...

Page 17: ...intenance work in a clean and dry environment e g workshop 4 9 1 Service Only have the machine repaired or serviced by technically trained personnel Only use original spare parts and accessories This...

Page 18: ...Components 1 3 4 2 5 1 2 3 4 5 6 6 1 Plug receptacle with protective cover 2 Winding aid 3 Carrying handle central suspension 4 Power cable 5 Ventilation slots 6 Deck Decks 1 2 3 4 5 6 1 Plug receptac...

Page 19: ...light Overtemperature 4 Control light Overcurrent 5 Control light Operation The control lights provide information about the operating status The control light lights up green when the machine is corr...

Page 20: ...aged labels and signs Safety labels contain important information to protect the operator Keep all safety warning and operating instructions on the machine in a clearly legible condition Replace missi...

Page 21: ...fting do not stand under suspended loads NOTICE Designate a competent instructor for a safe lifting procedure 1 1 Central suspension 1 Attach suitable sling to central suspension 1 2 Carefully load th...

Page 22: ...e expected if it is used in such a network Check whether the power supply or building site distributor has the correct operating voltage see type label of the machine or see Tech nical Data on page 30...

Page 23: ...on 1 Switch off all machines to be connected with the respective equip ment switch 2 If necessary connect the permissible power cable to the converter 3 Plug in the machine with the plug 4 Machine is...

Page 24: ...ce plan Activity Daily before opera tion After operation Visual inspection of all ele ments for damage Housing Power cable Handle Connection plug recept acle Clean the machine 9 1 2 Maintenance work 1...

Page 25: ...n one of the connected machines 2 phase operation with one of the con nected machines Mechanical defect in one of the connec ted machines 1 Perform reset Switch ma chine off and back on again 2 Discon...

Page 26: ...cted ma chines Machine is not working All three control lights Overvoltage overtem perature overcurrent light up red Power switch has been turned off Mains voltage is missing no malfunction 1 Switch t...

Page 27: ...x ample Malfunction Cause Remedy Intermediate deck 2 is not working Overtem perature control light lights up red Intermediate deck 2 has shut down due to high temperature 85 C 1 Allow intermediate dec...

Page 28: ...ue to self discharge of the accumulator The self discharge rate is approx 3 per month Deep discharge can cause damage to the cells or loss of capacity Store the accumulator with a charge condition of...

Page 29: ...ility This unit is intended as a professional electrical tool exclusively for com mercial use so called B2B device according to WEEE directive In con trast to equipment mainly used in private househol...

Page 30: ...ion The noise data listed has been determined in accordance with the follow ing guidelines for the typical machine operating conditions special test conditions and using harmonized standards Sound pre...

Page 31: ...Output current A 58 58 Output voltage V 42 0 42 Output frequency Hz 200 0 200 Nominal output power kW 3 4 0 3 4 Output phases 3 3 Length mm 516 516 Width mm 303 303 Height mm 420 420 Operating weight...

Page 32: ...torage temperature range C 25 50 C Protection class I Protection type IP44 Sound pressure level LpA dB A 70 13 4 Extension cable WARNING Danger from electric current Injury from electric shock Check p...

Page 33: ...m2 FUH35 2 042 230 1 63 1 5 105 2 5 167 4 0 FUH70 4 042 230 1 38 1 5 FUH70 4 042 SC 62 2 5 FUH70 6 042 SC Example You have a converter e g FUH70 4 042 and want to use an extension cable of 50 m length...

Page 34: ......

Page 35: ......

Page 36: ...Wacker Neuson Produktion GmbH Co KG Wackerstra e 6 D 85084 Reichertshofen Tel 49 8453 340 0 EMail service LE wackerneuson com www wackerneuson com Material number 5100056242 Language en...