 VLT 5000 Interbus card

The photo shows the Interbus card which can be

installed in VLT 5001 - 5500.

Name

Name

Name

Name

Name

Indicates

Indicates

Indicates

Indicates

Indicates

Color

Color

Color

Color

Color

On

On

On

On

On

OFF

OFF

OFF

OFF

OFF

CC/CR: Cable Check.

Green

Incoming bus active

Incoming bus swicthed off

BA

Bus Active.

Green

Bus active

Bus stopped

RD:

Status of outgoing bus. Red

Outgoing bus stopped

Outgoing bus active

TR:

Transmit/Receive.

Green

PCP Communication running

NO PCP Communication running

UL:

Power OK.

Green

Voltage within permissible range

No Voltage

All examples in this instruction are shown with a

PLC card as an Interbus master, but they are also

relevant to a PC system with an Interbus Master.

 Abstract

This application note describes how to set up

Interbus communication between a Danfoss VLT

5000 frequency converter and Interbus CMD G4.

CMD stand for Configuration Monotoring and

Diagnostics.

This note will describe:

 Configuring of the VLT 5000 and CMD

 Drivecom profile

 PCP communication

Interbus connection for Bookstyle

                   IBS IN         IBS OUT

                   IBS OUT        IBS IN

Interbus connection for Compact

TR

TR

CC/CR

RD

BA

RD

UL

UL

CC/CR

BA

LED identification

Summary of Contents for VLT 5000

Page 1: ...e Green PCP Communication running NO PCP Communication running UL Power OK Green Voltage within permissible range No Voltage All examples in this instruction are shown with a PLC card as an Interbus m...

Page 2: ...ad In is finished Please look at the bottom of the screen After the Read In CMD will indicate each VLT frequency converter with a DriveCom symbol a station number and an ID number Next step is to conf...

Page 3: ...ram profile must be set to Fieldbus option If you change the operating state from Online to Monitor you can write the control word and refe rence to the VLT frequency converter In Monitor state you ca...

Page 4: ...rol for controlling the VLT frequency converter Please notice that the control word will change when you change the states The control word is now 7F Hex Press Close The Manufactured Specific bits are...

Page 5: ...st row 55F1 Hex corresponds to 22001D This means that all VLT 5000 parameters simply can be accessed by adding 22000D to the VLT 5000 parameter For example if you want to write to parameter 207 Ramp u...

Page 6: ...PCD data The data for the VLT frequency converter in our PLC program starts at address 20 So we have to map address 20 to the Interbus card in the VLT frequency converter This is done with the CMD to...

Page 7: ...ontroller board and select Address Monitor P22 Input 201E Shows the actual reference from the VLT frequency converter P22 Output 2000 Hex Here you can write a reference tothe VLT frequency converter P...