Installation
4-40
AC30 series Variable Speed Inverter
Fitting a Remote GKP
When fitting the GKP remotely to either a cubicle or panel mount it
must
be fitted to a flat surface. Maximum cable length < 3 meters.
7001-00-00
– includes the GKP only
7001-00-01 - includes the GKP, 3m connection lead and screws.
If ordered and supplied with the inverter the connection lead is
NOT
supplied, to order the lead the part number is LA501991U300.
Cut out details:
Gasket
Reverse side of the
GKP
GKP
– Reverse side
The yellow dotted line is the cutout
detail to allow remote fitting the
connection lead, also shows screw
hole details.
Use M3 x 10 self tapping screws.
Connection lead RS232/REM OP
STA with a Steward 28A2025-OAO
connector.
All measurements in millimeter.
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...