D-64
Parameter Reference
AC30 series Variable Speed Drive
Feedbacks
Parameters::Motor Control::Feedbacks
The
Feedbacks
feature allows you to view speed feedback and motor current related diagnostics.
Parameter Name
No.
Path
Default
Range
Units
Writable
Duty Selection
0390
Setup::Motor Control::Control and Type
Parameters::Motor Control::Feedbacks
1
0:HEAVY DUTY
1:NORMAL DUTY
STOPPED
Heavy Duty
( typically 150%, 60s).
Normal Duty
allowing higher continuous ratings with less overload capability ( typically 110%, 60s).
% are related to the Drive/stack ratings.
For example, a 12A drive ( @4kHz ) under Normal Duty becomes a 10A drive ( @4kHz) under Heavy Duty
DC Link Voltage
0392
Monitor::Motor and Drive
Monitor::Regen Control
Parameters::Motor Control::Feedbacks
x.
0 to 1000
V
NEVER
This shows the voltage across the dc link capacitors.
Actual Speed RPM
0393
Monitor::Motor and Drive
Parameters:
:Motor
Control::Feedbacks
x.xx
-100000.00 to 100000.00
RPM
NEVER
This parameter changes according to the
Control Strategy:
In Vector Control mode the parameter shows the calculated mechanical speed of the motor shaft in rpm.
In Volts-Hertz Control mode the parameter shows motor synchronous speed in rpm.
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...