Parameter Reference
D-173
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
Inv Time Active
0353
Parameters::Motor Control::Stack Inv
Time
NEVER
The drive protection is limiting the output current
(*) : Depending on the frame size, overload capabilities are reduced when the electrical speed is below 3Hz and with the heatsink temperature. Refer
to Parker SSD for detailed values.
Above 3Hz electrical speed, overload capabilities are those defined by the
0390 Duty Selection
.
Functional Description
Stack Short overload
Stack Long overload
arbitration
Motor overload (
150%, 60s)
Min
Feedback Amps
Move to Stack %
Convert to Motor %
Convert to Motor %
Motor Load (Only for IM Motor)
Inv Time in Motor %
Inv Time Output
Short Overload : is using 180% of the Heavy Duty rating, for 3s.
Long Overload : is using the overload mode selected in
0390 Duty Selection
.
Inv Time in Motor %
is used to limit the current. It is one of the inputs of the
Current Limit
Function features
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...