Speed Error Trip
Parameters::Trips::Speed Error Trip
This function allows the user to program the response of the drive in a situation where persistent speed error (as a difference between setpoint and
actual measured or estimated speed) occurs.
Parameter Name
No.
Path
Default
Range
Units
Writable
Speed Error Trip Enable
1746
Parameters::Trips::Speed Error Trip
FALSE
ALWAYS
A boolean that enables the speed error trip.
Speed Error Threshold
1747
Parameters::Trips::Speed Error Trip
100.00
0.00 to 100.00
%
ALWAYS
Level of speed error required to trigger the trip.
Speed Error Trip Delay
1748
Parameters::Trips::Speed Error Trip
10.000
0.000 to 2000.000
s
ALWAYS
Time period after which the drive trips. After half of this time a warning is issued.
Functional Description
If the difference between the setpoint and the actual motor speed is greater than a level defined in parameter 1747
(Speed Error Threshold)
for a period longer than time defined in parameter 1748
(Speed Error Trip Delay)
, the drive will trip. After half of that period a warning will be
produced. This is only operational if enabled via parameter 1746
(Speed Error Trip Enable).
.
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...