![Parker AC30 series User Manual Download Page 220](http://html2.mh-extra.com/html/parker/ac30-series/ac30-series_user-manual_3745313220.webp)
C-7
Compliance
AC30 series Variable Speed Inverter
Standard EN 61800-3
Frame G
Frame H
45kW
Frame H
55kW & 75kW
Frame J
132kW
Frame K
250kW
C
on
du
ct
ed
E
mi
ss
ion
s
A
C
S
up
po
rte
d
In
ve
rte
rs
Category C1
Not suitable for use in this environment
Category C2
When fitted with an EMC filter kit (internal filter, clamping bracket and ferrite)
Maximum cable length 10 m
When fitted with the specified external
filter & EMC filter kit, refer to C17
Maximum cable length 25 m
Please contact Parker
for more information
Category C3
Where I<=100A
When fitted with an internal filter
Maximum cable length 50 m
n/a
Category C3
Where I>=100A
n/a
When fitted with an internal filter
Maximum cable length 50 m
Standard build
Maximum cable length 50 m
D
C
S
up
pli
ed
S
ys
te
m
Category C3
When supplied by AC to DC full bridge and required line choke. Maximum cable length 50 m.
Not applicable
R
ad
iat
ed
E
mi
ss
ion
s
When mounted inside a cubicle with the required attenuation between:
Category C1
Not Applicable
Category C2
30-1000MHz at 10dB
Category C3
No specific enclosure required
C
ab
le
R
eq
uire
men
ts
Power Supply
Cable Type
Unscreened
Segregation
From all other wiring (clean)
Length Limit
Unlimited
Motor Cable
Cable Type
Screened/Armoured
Segregation
From all other wiring (noisy)
Screen to Earth
Both ends
Output Choke
300 meters maximum
External Filter
to Drive
Cable Type
Screened/Armoured
Segregation
From all other wiring (noisy)
Length Limit
0.3 meters
Screen to Earth
Both ends
Brake Resistor Cable Type
Screened/Armoured
Segregation
From all other wiring (noisy)
Length Limit
25 meters
Screen to Earth
Both ends
Signal/Control
Cable Type
Screened
Segregation
From all other wiring (sensitive)
Length Limit
25 meters
Screen to Earth
Drive end only
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...