D-218
Parameter Reference
AC30 series Variable Speed Drive
PNO Name
Path
Type
Default
Range
Units
WQ
View
Notes MBus
1277 Monitor[6]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03081
1278 Monitor[7]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03083
1279 Monitor[8]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03085
1280 Monitor[9]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03087
1281 Monitor[10]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03089
1282 Monitor[11]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03091
1283 Monitor[12]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03093
1284 Monitor[13]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03095
1285 Monitor[14]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03097
1286 Monitor[15]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03099
1287 Monitor[16]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03101
1288 Monitor[17]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03103
1289 Monitor[18]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03105
1290 Monitor[19]
Same as PNO 1271
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03107
1311 Setup
Parameters::Device Manager::Soft Menus
ARRAY[0..19]
ALWAYS OPERATOR
03149
1312 Setup[0]
Setup::Quick Setup
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03151
1313 Setup[1]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03153
1314 Setup[2]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03155
1315 Setup[3]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03157
1316 Setup[4]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03159
1317 Setup[5]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03161
1318 Setup[6]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03163
1319 Setup[7]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03165
1320 Setup[8]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03167
1321 Setup[9]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03169
1322 Setup[10]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03171
1323 Setup[11]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03173
1324 Setup[12]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03175
1325 Setup[13]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03177
1326 Setup[14]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03179
1327 Setup[15]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03181
1328 Setup[16]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03183
1329 Setup[17]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03185
1330 Setup[18]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03187
1331 Setup[19]
Same as PNO 1312
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03189
1352 Control Screen
Parameters::Device Manager::Soft Menus
ARRAY[0..5]
ALWAYS OPERATOR
03231
1353 Control Screen[0]
Control Screen
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03233
1354 Control Screen[1]
Same as PNO 1353
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03235
1355 Control Screen[2]
Same as PNO 1353
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03237
1356 Control Screen[3]
Same as PNO 1353
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03239
1357 Control Screen[4]
Same as PNO 1353
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03241
1358 Control Screen[5]
Same as PNO 1353
UINT
0000
0000 to 2149
ALWAYS OPERATOR
2
03243
1387 PMAC Base Volt
Setup::Motor Control::Motor Data PMAC
Parameters::Motor Control::PMAC Motor Data
REAL
400.00
0.00 to 1000.00
V
ALWAYS TECHNICIAN 6
03301
1388 ATN PMAC Test Disable
Setup::Motor Control::Autotune
Parameters::Motor Control::Autotune
WORD
(bitfield)
0000
0:Stator Resistance
1:Leakage Inductance
2:KE Constant
STOPPED TECHNICIAN 6
03303
1389 ATN PMAC Test Disable.Stator Resistance
Same as PNO 1388
BOOL
FALSE
STOPPED TECHNICIAN 6
03305
1390 ATN PMAC Test Disable.Leakage Inductance
Same as PNO 1388
BOOL
FALSE
STOPPED TECHNICIAN 6
03307
1391 ATN PMAC Test Disable.KE Constant
Same as PNO 1388
BOOL
FALSE
STOPPED TECHNICIAN 6
03309
1405 ATN PMAC Ls Test Freq
Same as PNO 1388
REAL
100.0
0.0 to 500.0
Hz
STOPPED ENGINEER
6
03337
1406 HV Power On Count
Parameters::Device Manager::Runtime Statistics
UINT
0 to 65535
NEVER
TECHNICIAN 1
03339
1407 Motor Run Time
Parameters::Device Manager::Runtime Statistics
UDINT
0 to Max
s
NEVER
TECHNICIAN 1
03341
1408 Warranty Trips Record
Parameters::Trips::Trips History
DWORD
(bitfield)
0:01 OVER VOLTAGE
2:03 OVER CURRENT
3:04 STACK FAULT
4:05 STACK OVER CURRENT
7:08 INVERSE TIME
10:11 HEATSINK OVERTEMP
11:12 INTERNAL OVERTEMP
14:15 BRAKE SHORT CCT
16:17 BRAKE SWITCH
21:22 VDC RIPPLE
NEVER
ENGINEER
1
03343
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...