Parameter Reference
D-221
AC30 series Variable Speed Drive
PNO Name
Path
Type
Default
Range
Units
WQ
View
Notes MBus
1534 Clone Filename
Setup::Clone
Parameters::Device Manager::Clone
STRING[24]
clone
ALWAYS TECHNICIAN 2
03595
1537 Clone Direction
Same as PNO 1534
USINT
(enum)
0
0:SAVE TO FILE
1:LOAD FROM FILE
ALWAYS TECHNICIAN 2
03601
1538 Full Restore
Same as PNO 1534
USINT
(enum)
0
0:YES
1:PARTIAL
ALWAYS TECHNICIAN 2
03603
1539 Application
Same as PNO 1534
USINT
(enum)
0
0:LOAD FROM FILE
1:LEAVE CURRENT APP
ALWAYS TECHNICIAN 2
03605
1540 Other Parameters
Same as PNO 1534
USINT
(enum)
0
0:LOAD FROM FILE
1:LEAVE CURRENT VALUES
2:SET TO DEFAULT VALUES
ALWAYS TECHNICIAN 2
03607
1541 Power Parameters
Same as PNO 1534
USINT
(enum)
0
Same as PNO 1540
ALWAYS TECHNICIAN 2
03609
1542 Clone Start
Same as PNO 1534
BOOL
FALSE
ALWAYS TECHNICIAN 2
03611
1543 Clone Status
Same as PNO 1534
USINT
(enum)
0:IDLE
1:SAVING
2:RESTORING
3:VERIFYING
4:DONE
5:CANNOT START
6:FAILED
7:NO SD CARD
8:VERIFY FAILED
9:FILE NOT OPENED
10:FILE INCOMPATIBLE
11:FILE FAILURE
12:POWER MISMATCH
13:APPLICATION FAILURE
14:PARAMETERS FAILURE
NEVER
TECHNICIAN
03613
1544 Filter Type
Parameters::Motor Control::Filter On Torque Dmd USINT
(enum)
0
0:NONE
1:MAX ATTENUATION
2:MINIMUM PHASE
3:PHASE ADVANCE
4:NOTCH
ALWAYS TECHNICIAN
03615
1545 Cut Off Frequency
Parameters::Motor Control::Filter On Torque Dmd REAL
2000
20 to 6000
Hz
ALWAYS TECHNICIAN
03617
1546 Frequency 1
Parameters::Motor Control::Filter On Torque Dmd REAL
2000
20 to 6000
Hz
ALWAYS TECHNICIAN
03619
1547 Frequency 2
Parameters::Motor Control::Filter On Torque Dmd REAL
2000
20 to 6000
Hz
ALWAYS TECHNICIAN
03621
1548 Factor
Parameters::Motor Control::Filter On Torque Dmd REAL
0.20
0.10 to 1.00
ALWAYS TECHNICIAN
03623
1549 Application Volts
Parameters::Motor Control::Fluxing VHz
REAL
0.00
0.00 to 150.00
%
ALWAYS OPERATOR
03625
1550 Nameplate Mag Current
Setup::Motor Control::Autotune
Parameters::Motor Control::Autotune
REAL
1.00
0.01 to 1000.00
A
STOPPED TECHNICIAN 6
03627
1551 Product Code Flags
Parameters::Device Manager::Drive info
BYTE
NEVER
ENGINEER
03629
1554 Application Name
Parameters::Application::App Info
STRING[20]
NEVER
TECHNICIAN
03635
1560 Start Delay Enable
Parameters::Motor Control::Motor Sequencer
BOOL
FALSE
STOPPED TECHNICIAN
03647
1565 Local Power Up Mode
Parameters::Motor Control::Sequencing
USINT
(enum)
0
0:AS WHEN POWERED DOWN
1:LOCAL
2:REMOTE
ALWAYS TECHNICIAN
03657
1567 Modbus Mapping
Setup::Communications::Base Modbus
Parameters::Base Comms::Modbus
ARRAY[0..15]
ALWAYS ENGINEER
03661
1568 Modbus Mapping[0]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03663
1569 Modbus Mapping[1]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03665
1570 Modbus Mapping[2]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03667
1571 Modbus Mapping[3]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03669
1572 Modbus Mapping[4]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03671
1573 Modbus Mapping[5]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03673
1574 Modbus Mapping[6]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03675
1575 Modbus Mapping[7]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03677
1576 Modbus Mapping[8]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03679
1577 Modbus Mapping[9]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03681
1578 Modbus Mapping[10]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03683
1579 Modbus Mapping[11]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03685
1580 Modbus Mapping[12]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03687
1581 Modbus Mapping[13]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03689
1582 Modbus Mapping[14]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03691
1583 Modbus Mapping[15]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS ENGINEER
03693
1632 Mapping Valid
Monitor::Communications::Base Modbus
Parameters::Base Comms::Modbus
BOOL
NEVER
OPERATOR
03791
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...