Parameter Reference
D-141
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
Ramp Speed Output
0500
Parameters::Motor Control::Ramp
x.x
-200.0 to 200.0
%
NEVER
Output speed
Jog Setpoint
0501
Parameters::Motor Control::Ramp
10.0
0.0 to 100.0
%
ALWAYS
The setpoint is the target reference that the Drive will ramp to
Jog Acceleration Time
0502
Parameters::Motor Control::Ramp
1.000
0.000 to 3000.000
s
ALWAYS
The time that the Drive will take to ramp the jog setpoint from 0.00% to 100.00%.
Jog Deceleration Time
0503
Parameters::Motor Control::Ramp
1.000
0.000 to 3000.000
s
ALWAYS
The time that the Drive will take to ramp the jog setpoint from 100.00% to 0.00%.
Stop Ramp Time
0504
Same as PNO 484
10.000
0.000 to 600.000
s
ALWAYS
Rate at which the demand is ramped to zero after the ramp has been quenched
Zero Speed Threshold
0505
Parameters::Motor Control::Ramp
0.1
0.0 to 100.0
%
ALWAYS
Hold for zero speed detection used by stop sequences
Zero Speed Stop Delay
0506
Parameters::Motor Control::Ramp
0.500
0.000 to 30.000
s
ALWAYS
Sets the time at which the Drive holds zero speed before quenching after a normal stop or a jog stop. This may be particularly useful if
a mechanical brake requires time to operate at zero speed, or for jogging a machine to position
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...