Parameter Name
No.
Path
Default
Range
Units
Writable
AR Restart Pending
1508
Parameters::Motor Control::Auto Restart
NEVER
Indicates that the AR feature will reset the trip source and attempt to restart the motor once all trips have become inactive and the
relevant delay timer has expired.
AR Restarts Remaining
1509
Parameters::Motor Control::Auto Restart
0 to 20
NEVER
Indicates the number of restart attempts remaining before the AR feature disables itself.
This count is reset to
1471 AR Max Restarts
after a successful manual or remote trip reset. The count is also reset after a period of
trip free operation. This period is the longer of 5 minutes, or 5 * AR Repeat Delay B.
AR Time Remaining
1510
Parameters::Motor Control::Auto Restart
0.000 to 3600.000
s
NEVER
Indicates the time remaining before a restart attempt will be made. This value starts to count down once all trip sources are inactive.
Functional Description
The AR feature can be configured to operate in one of three modes via the parameter
1470 AR Mode
.
In all modes the AR feature becomes active when the drive trips on one of the trips selected by parameter
1472 AR Trip Mask
. If the drive trips due
to a trip not selected in
1472 AR Trip Mask
the AR feature will remain in the idle state.
Setting parameter
1469 AR Enable
to FALSE will disable the AR feature regardless of its current state.
1470 AR Mode 0:
Trip Reset
In Trip Reset mode, once the AR feature becomes active it monitors all possible trip sources. Once all trip sources are inactive the AR feature will
attempt to reset the trip event, moving the Sequencing State from the FAULTED state, (see Appendix B: Sequencing Logic). The AR feature resets
the trip as soon as possible, it does not wait for either
1505 Initial Delay
or
1506 AR Repeat Delay
.
In this mode the AR feature will not attempt to restart the motor.
This mode may be used when an external supervisiory system is monitoring the Faulted bit in
0661 Status Word
. This bit will be cleared once all trip
sources are inactive and the trip has been successfully cleared, indicating that the drive may be started.
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...