![Parker AC30 series User Manual Download Page 358](http://html2.mh-extra.com/html/parker/ac30-series/ac30-series_user-manual_3745313358.webp)
D-98
Parameter Reference
AC30 series Variable Speed Drive
Minimum Speed
Setup::Application::Minimum Speed
Function availability depends on macro selected.
The minimum speed function is used to determine how the AC30V will follow a reference.
Parameter Name
No.
Path
Default
Range
Units
Writable
Minimum Speed Value
1906
Setup::Application::Minimum Speed
-100.0
-100.0 to 100.0
%
ALWAYS
Specifies the minimum output value.
Minimum Speed Mode
1907
Setup::Application::Minimum Speed
0
0:PROP WITH MINIMUM
1:LINEAR
ALWAYS
There are two modes of operation.
Functional Description
Min
0
100%
100
-100
input
output
There are two operating modes for the
MINIMUM SPEED
function:
PROP WITH MINIMUM (proportional with minimum)
In this mode the
MINIMUM SPEED
function behaves like a simple clamp. The
Minimum Speed Value
has the valid range -100% to 100% and the
output is always greater than or equal to the
Minimum Speed Value
.
LINEAR
In this mode the
MINIMUM SPEED
function first clamps the input to zero then rescales the input such that the output goes linearly between
minimum and 100% for an input that goes from 0 to 100%.
Note the constraints:-
min >= 0
input >= 0
max = 100%
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...