![Parker AC30 series User Manual Download Page 431](http://html2.mh-extra.com/html/parker/ac30-series/ac30-series_user-manual_3745313431.webp)
Parameter Reference
D-171
AC30 series Variable Speed Drive
Stack Inv Time
Parameters::Motor Control::Stack Inv Time
The purpose of the inverse time is to automatically reduce the drive current limit in response to prolonged overload conditions.
For a short time given by
Short Overload Time
, the drive is able to provide the
Short Overload Level
For a long time given by
Long Overload Time
, the drive is able to provide the
Long Overload Level
These 2 protections work in parallel, the output limit current is the maximum value if
Inv Time Active
= False. If
Inv Time Active
= True, the
current limit is determined by
Long Overload Level
the current limit is not yet ramped down. If already ramped down, the current limit is due to the long overload.
When the maximum overload value is reached, the inverse time current limit is ramped down. The rate at which the inverse time current limit is
ramped to the
Inv Aiming Point
is defined by
Inv Time Down Rate
. When the overload condition disappears, the inverse time current limit is ramped
up. The rate at which the inverse time current limit is ramped to the maximum value is defined by
Inv Time Up Rate.
% Are all referring to drive/stack ratings.
Parameter Name
No.
Path
Default
Range
Units
Writable
100% Stk Current
0343
Parameters::Motor Control::Stack Inv
Time
x.x
0.0 to 10000.0
A
NEVER
Stack rating in rms amps corresponding to 100% stack current
Long Overload Level
0344
Parameters::Motor Control::Stack Inv
Time
x.
0 to 200
%
NEVER
Overload value in % of the stack amps for long overload condition(*)
Long Overload Time
0345
Parameters::Motor Control::Stack Inv
Time
0.000 to 100000.000
s
NEVER
Maximum duration under long overload condition (typically 60s)
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...