Parameter Reference
D-207
AC30 series Variable Speed Drive
PNO Name
Path
Type
Default
Range
Units
WQ
View
Notes MBus
0508 Quickstop Ramp Time
Parameters::Motor Control::Ramp
TIME
0.100
0.000 to 600.000
s
ALWAYS TECHNICIAN
01543
0509 Final Stop Rate
Parameters::Motor Control::Ramp
REAL
1200
1 to 4800
Hz/s
ALWAYS TECHNICIAN
01545
0511 Motor Type or AFE
Setup::Motor Control::Control and Type
Setup::Regen Control
Parameters::Control Mode::Control Mode
USINT
(enum)
0
0:INDUCTION MOTOR
1:PMAC MOTOR
STOPPED TECHNICIAN 6
01549
0512 Control Strategy
Setup::Motor Control::Control and Type
Parameters::Control Mode::Control Mode
USINT
(enum)
0
0:VOLTS - HERTZ CONTROL
1:VECTOR CONTROL
STOPPED TECHNICIAN 6
01551
0513 Active 33 - 64
Monitor::Trips
Parameters::Trips::Trips Status
DWORD
NEVER
OPERATOR
01553
0514 Warnings 33 - 64
Same as PNO 513
DWORD
NEVER
OPERATOR
01555
0515 Speed Loop Pgain
Parameters::Motor Control::Spd Loop Settings
REAL
20.00
0.00 to 3000.00
ALWAYS TECHNICIAN
01557
0516 Speed Loop I Time
Parameters::Motor Control::Spd Loop Settings
TIME
0.100
0.001 to 1.500
s
ALWAYS TECHNICIAN
01559
0517 Speed Loop Int Defeat
Parameters::Motor Control::Spd Loop Settings
BOOL
FALSE
ALWAYS TECHNICIAN
01561
0518 Speed Loop Int Preset
Parameters::Motor Control::Spd Loop Settings
REAL
0
-500 to 500
ALWAYS TECHNICIAN
01563
0519 Spd Loop Dmd Filt TC
Parameters::Motor Control::Spd Loop Settings
REAL
0.0
0.0 to 15.0
ms
ALWAYS TECHNICIAN
01565
0520 Spd Loop Fbk Filt TC
Parameters::Motor Control::Spd Loop Settings
REAL
1.0
0.0 to 15.0
ms
ALWAYS TECHNICIAN
01567
0521 Spd Loop Aux Torq Dmd
Parameters::Motor Control::Spd Loop Settings
REAL
0.00
-300.00 to 300.00
%
ALWAYS TECHNICIAN
01569
0523 Spd Loop Adapt Thres
Parameters::Motor Control::Spd Loop Settings
REAL
0.00
0.00 to 10.00
%
ALWAYS TECHNICIAN
01573
0524 Spd Loop Adapt Pgain
Parameters::Motor Control::Spd Loop Settings
REAL
20.00
0.00 to 300.00
ALWAYS TECHNICIAN
01575
0525 Spd Demand Pos Lim
Parameters::Motor Control::Spd Loop Settings
REAL
110.00
-110.00 to 110.00
%
ALWAYS TECHNICIAN
01577
0526 Spd Demand Neg Lim
Parameters::Motor Control::Spd Loop Settings
REAL
-110.00
-110.00 to 110.00
%
ALWAYS TECHNICIAN
01579
0527 Sel Torq Ctrl Only
Parameters::Motor Control::Spd Loop Settings
BOOL
FALSE
ALWAYS TECHNICIAN
01581
0528 Direct Input Select
Parameters::Motor Control::Spd Direct Input
USINT
(enum)
0
0:NONE
1:ANIN1
2:ANIN2
ALWAYS TECHNICIAN
01583
0529 Direct Input Ratio
Parameters::Motor Control::Spd Direct Input
REAL
1.0000
-10.0000 to 10.0000
ALWAYS TECHNICIAN
01585
0530 Direct Input Pos Lim
Parameters::Motor Control::Spd Direct Input
REAL
110.00
-110.00 to 110.00
%
ALWAYS TECHNICIAN
01587
0531 Direct Input Neg Lim
Parameters::Motor Control::Spd Direct Input
REAL
-110.00
-110.00 to 110.00
%
ALWAYS TECHNICIAN
01589
0533 Total Spd Demand RPM
Parameters::Motor Control::Spd Loop Diagnostics REAL
x.xx
-100000.00 to 100000.00
RPM
NEVER
TECHNICIAN
01593
0534 Total Spd Demand %
Parameters::Motor Control::Spd Loop Diagnostics REAL
x.xx
-200.00 to 200.00
%
NEVER
TECHNICIAN
01595
0535 Speed Loop Error
Parameters::Motor Control::Spd Loop Diagnostics REAL
x.xx
-400.00 to 400.00
%
NEVER
TECHNICIAN
01597
0536 Speed PI Output
Parameters::Motor Control::Spd Loop Diagnostics REAL
x.xx
-500.00 to 500.00
%
NEVER
TECHNICIAN
01599
0543 Power Stack Fitted
Parameters::Device Manager::Drive info
USINT
(enum)
0:NONE
1:3.5 A 400 V
2:4.5 A 400 V
3:5.5 A 400 V
4:7.5 A 400 V
5:10.0 A 400 V
6:12.0 A 400 V
7:16.0 A 400 V
8:23.0 A 400 V
9:32.0 A 400 V
10:38.0 A 400 V
11:45.0 A 400 V R1
12:60.0 A 400 V R1
13:73.0 A 400 V R1
14:87.0 A 400 V
15:105 A 400 V
16:145 A 400 V
17:180 A 400 V
18:205 A 400 V
19:260 A 400 V
20:45.0 A 400 V
21:60.0 A 400 V
22:73.0 A 400 V
23:315 A 400 V
24:380 A 400 V
25:440 A 400 V
NEVER
TECHNICIAN
01613
0555 PMAC Max Speed
Setup::Motor Control::Motor Data PMAC
Parameters::Motor Control::PMAC Motor Data
REAL
3000
0 to 100000
RPM
ALWAYS TECHNICIAN 6
01637
0556 PMAC Max Current
Same as PNO 555
REAL
4.50
0.00 to 5000.00
A
ALWAYS TECHNICIAN 6
01639
0557 PMAC Rated Current
Same as PNO 555
REAL
4.50
0.00 to 5000.00
A
ALWAYS TECHNICIAN 6
01641
0558 PMAC Rated Torque
Same as PNO 555
REAL
4.50
0.00 to 30000.00
Nm
ALWAYS TECHNICIAN 6
01643
0559 PMAC Motor Poles
Same as PNO 555
UINT
10
0 to 400
ALWAYS TECHNICIAN 6
01645
0560 PMAC Back Emf Const KE
Same as PNO 555
REAL
60.0
0.0 to 30000.0
V
ALWAYS TECHNICIAN 6
01647
0561 PMAC Winding Resistance
Same as PNO 555
REAL
6.580
0.000 to 50.000
Ohm
ALWAYS TECHNICIAN 6
01649
0562 PMAC Winding Inductance
Same as PNO 555
REAL
20.00
0.00 to 1000.00
mH
ALWAYS TECHNICIAN 6
01651
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...