![Parker AC30 series User Manual Download Page 463](http://html2.mh-extra.com/html/parker/ac30-series/ac30-series_user-manual_3745313463.webp)
Parameter Reference
D-203
AC30 series Variable Speed Drive
PNO Name
Path
Type
Default
Range
Units
WQ
View
Notes MBus
2:500 KBPS
3:AUTO
0221 DeviceNet Actual Baud
Same as PNO 218
USINT
(enum)
Same as PNO 220
NEVER
OPERATOR
00969
0222 DNet Producing Inst
Same as PNO 219
WORD
0064
CONFIG TECHNICIAN
00971
0223 DNet Consuming Inst
Same as PNO 219
WORD
0096
CONFIG TECHNICIAN
00973
0224 EtherCAT State
Monitor::Communications::Option
Parameters::Option Comms::EtherCAT
USINT
(enum)
0:SETUP
1:NW INIT
2:INIT OR PREOP
3:SAFE OPERATIONAL
4:OPERATIONAL
5:ERROR
6:RESERVED
7:EXCEPTION
8:NONE
NEVER
OPERATOR
00975
0225 EtherNet IP State
Monitor::Communications::Option
Parameters::Option Comms::EtherNet IP
USINT
(enum)
Same as PNO 214
NEVER
OPERATOR
00977
0226 ENet Producing Inst
Setup::Communications::Option
Parameters::Option Comms::EtherNet IP
WORD
0064
CONFIG TECHNICIAN
00979
0227 ENet Consuming Inst
Same as PNO 226
WORD
0096
CONFIG TECHNICIAN
00981
0228 Modbus RTU State
Monitor::Communications::Option
Parameters::Option Comms::Modbus RTU
USINT
(enum)
Same as PNO 46
NEVER
OPERATOR
00983
0229 Modbus Device Address
Setup::Communications::Option
Parameters::Option Comms::Modbus RTU
USINT
1
1 to 247
CONFIG TECHNICIAN 7
00985
0230 Modbus RTU Baud Rate
Same as PNO 229
USINT
(enum)
4
0:1200 BPS
1:2400 BPS
2:4800 BPS
3:9600 BPS
4:19200 BPS
5:38400 BPS
6:57600 BPS
7:76800 BPS
8:115200 BPS
CONFIG TECHNICIAN
00987
0231 Parity And Stop Bits
Same as PNO 229
USINT
(enum)
0
0:EVEN, 1 STOP
1:ODD, 1 STOP
2:NONE, 2 STOP
3:NONE, 1 STOP
CONFIG TECHNICIAN
00989
0232 High Word First RTU
Same as PNO 229
BOOL
FALSE
CONFIG TECHNICIAN
00991
0233 Modbus RTU Timeout
Same as PNO 229
TIME
3.000
0.000 to 65.000
s
CONFIG TECHNICIAN
00993
0234 Modbus TCP State
Monitor::Communications::Option
Parameters::Option Comms::Modbus TCP
USINT
(enum)
Same as PNO 46
NEVER
OPERATOR
00995
0235 High Word First TCP
Setup::Communications::Option
Parameters::Option Comms::Modbus TCP
BOOL
FALSE
CONFIG TECHNICIAN
00997
0236 Modbus TCP Timeout
Same as PNO 235
TIME
3.000
0.000 to 65.000
s
CONFIG TECHNICIAN
00999
0237 Profibus State
Monitor::Communications::Option
Parameters::Option Comms::Profibus
USINT
(enum)
Same as PNO 46
NEVER
OPERATOR
01001
0238 Profibus Node Address
Setup::Communications::Option
Parameters::Option Comms::Profibus
USINT
0
0 to 126
CONFIG TECHNICIAN 7
01003
0239 PROFINET State
Monitor::Communications::Option
Parameters::Option Comms::PROFINET IO
USINT
(enum)
0:SETUP
1:NW INIT
2:WAITING TO CONNECT
3:STOP MODE
4:CONNECTED
5:ERROR
6:RESERVED
7:EXCEPTION
8:NONE
NEVER
OPERATOR
01005
0240 PROFINET Device Name
Same as PNO 239
STRING[32]
NEVER
OPERATOR
01007
0249 Braking Enable
Parameters::Motor Control::Braking
BOOL
TRUE
ALWAYS TECHNICIAN 6
01025
0251 Brake Resistance
Parameters::Motor Control::Braking
REAL
100.00
0.01 to 1000.00
Ohm STOPPED TECHNICIAN 6
01029
0252 Brake Rated Power
Parameters::Motor Control::Braking
REAL
0.10
0.10 to 510.00
kW
STOPPED TECHNICIAN 6
01031
0253 Brake Overrating
Parameters::Motor Control::Braking
REAL
25.00
1.00 to 40.00
STOPPED ENGINEER
6
01033
0254 Braking Active
Parameters::Motor Control::Braking
BOOL
NEVER
TECHNICIAN
01035
0255 Autotune Enable
Setup::Motor Control::Autotune
Parameters::Motor Control::Autotune
BOOL
FALSE
STOPPED TECHNICIAN 2
01037
0256 Autotune Mode
Same as PNO 255
USINT
(enum)
1
0:STATIONARY
1:ROTATING
STOPPED TECHNICIAN 6
01039
Summary of Contents for AC30 series
Page 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Page 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Page 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Page 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Page 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Page 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Page 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Page 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Page 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Page 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Page 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...