17. Didital Diagnostic Monitoring (DDM) Commands
147
17.11. show ddm ports status
Description
This command is used to show the current operating DDM parameters values of the optic
module of the specified ports. This command displays the current operating parameters of
the optic modules.
Format
show ddm ports {<portlist> } status
Parameters
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To show port 21-23's operating parameters:
ports
<portlist>
Specifies a range of ports to be displayed.
If the port parameter is not specified, all optic ports' operating parameters will be
displayed.
Zxxx0:admin# show ddm ports 21-23 status
Command: show ddm ports 21-23 status
Port
Temperature
Voltage
Bias-Current
TX-Power
RX-Power
(in Celsius) (V)
(mA)
(dBm)
(dBm)
------ ------------- --------- ------------- ---------- -----------
21 - - - - -
22 25.0625 3.5036 12.6473 -9.9097 -5.4166
23 - - - - -
CTRL+C ESC q Quit SPACE n Next Page p Previous Page r Refresh