44. Network Management Commands
395
44.Network Management Commands
SNMP (Simple Network Management Protocol) is a protocol to monitor and
manage network-connected devices via network. Target devices have a
management information database called MIB (Management Information
Base). SNMP monitors and controls them through access to their MIBs
using an external management manager.
44.1. enable snmp
Description
This command is used to enable the SNMP function. When SNMP function is disabled, the
network manager will not be able to access SNMP MIB objects. The device will not send
traps or notification to network manager either.
enable snmp
disable snmp
create trusted_host [<ipaddr> | <ipv6addr> | network <network_address> | ipv6_prefix
<ipv6networkaddr>] {snmp | telnet | ssh | http | https | ping}
config trusted_host [<ipaddr> | <ipv6addr> | network <network_address> | ipv6_prefix
<ipv6networkaddr>] [add | delete] {snmp | telnet | ssh | http | https | ping | all}
delete trusted_host [ipaddr <ipaddr> | ipv6address <ipv6addr> | network <network_address>|
ipv6_prefix <ipv6networkaddr> | all]
show trusted_host
config snmp system_name <sw_name>
config snmp system_location <sw_location>
config snmp system_contact <sw_contact>
enable snmp traps
disable snmp traps
enable snmp authenticate_traps
disable snmp authenticate_traps
enable snmp linkchange_traps
disable snmp linkchange_traps
show snmp traps {linkchange_traps {ports <portlist>}}
config snmp linkchange_traps ports [all | <portlist>] [enable | disable]
config snmp coldstart_traps [enable | disable]
config snmp warmstart_traps [enable | disable]
config trap source_ipif [<ipif_name 12> {<ipaddr> | <ipv6addr>} | none]
show trap source_ipif
config rmon trap {rising_alarm [enable | disable] | falling_alarm [enable | disable]}
show rmon
Summary of Contents for ZEQUO 2200
Page 3: ...3 ...
Page 86: ...7 ARP Commands 86 ...
Page 93: ...9 Auto Configuration Commands 93 ...
Page 273: ...30 IPv6 NDP Commands 273 ...
Page 330: ...36 LLDP Commands 330 ...
Page 361: ...39 MAC based Access Control Commands 361 ...
Page 461: ...49 Protocol VLAN Commands 461 ...
Page 483: ...50 QoS Commands 483 ...
Page 504: ...53 SNMPv1 v2 v3 Commands 504 Only Administrator level users can issue this command ...
Page 523: ...53 SNMPv1 v2 v3 Commands 523 ...
Page 562: ...57 Subnet VLAN Commands 562 ...