3. Connection
17
3. Connection
3.1.
Connecting a Copper Cable Port
● Connection Cable
Use a CAT5e or higher compliant straight cable (copper cabling) with 8P8C RJ45 mod
-
ular plugs.
● Network Configuration
Fig. 3-1 Connection Configuration Example
The length of the cable connecting this Switching Hub and a device must be 100 m or
shorter. When a terminal or a LAN device with auto negotiation function is connected
to a port, the port is automatically configured to the most appropriate performance
mode. When a terminal or a device without auto negotiation function is connected to
a port, this Switching Hub automatically determines and sets the communication
speed; however, the full/half-duplex configuration is set at half-duplex because the
full/half-duplex capability cannot be determined. When connecting a terminal or a
device without auto negotiation function, set the connection mode of the port to
Fixed.
Note
: If connection mode is set to a fixed value, Auto MDI/MDI-X function does not
work. Therefore, you need to use a cross cable for connections between
Switching Hubs.