13. Cable Diagnostics Commands
114
For Gigabit Ethernet ports:
•
Where the link partner is powered on with no errors and the link is up, this
command cannot detect the cable length.
•
Where the link partner is powered on with errors, this command can detect
whether the error is open, short, or crosstalk. In this case this command can also
detect the distance of the error.
•
Where the link partner is powered down with no errors and the link is down, this
command cannot detect the cable length.
•
When the link partner is powered down with errors, this command can detect
whether the error is open, short, or crosstalk. In this case this command can also
detect the distance of the error.
•
When there is no link partner with no errors and the link is up, this command can
detect the cable length.
•
When there is no link partner with errors, this command can detect whether the
error is open, short, or crosstalk. In this case this command can also detect the
distance of the error.
The Cable length range that can be detected is as follows:
•
Smaller than 50m (<50m)
•
Between 50m and 80m (50m~80m)
•
Between 80m and 100m (80m~100m)
•
Greate than 100m (>100m)
The cable length deviation value is 5m, therefore if the cable length is lest than 5m,
'
No Cable
'
may be displayed under the
'
Test Result
'
column.
This test will consume a low number of packets. Since this test is for
copper cable, the port with fiber cable will be skipped from the test.
Format
cable_diag ports [<portlist> | all]
Parameters
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To test the cable on ports 1 to 4, and 8:
<portlist>Specify a range of ports to be configured.
<portlist>Specify to set all ports in the system.
ワヰヵユ
ワヰヵユ
Summary of Contents for ZEQUO 2200
Page 3: ...3 ...
Page 86: ...7 ARP Commands 86 ...
Page 93: ...9 Auto Configuration Commands 93 ...
Page 273: ...30 IPv6 NDP Commands 273 ...
Page 330: ...36 LLDP Commands 330 ...
Page 361: ...39 MAC based Access Control Commands 361 ...
Page 461: ...49 Protocol VLAN Commands 461 ...
Page 483: ...50 QoS Commands 483 ...
Page 504: ...53 SNMPv1 v2 v3 Commands 504 Only Administrator level users can issue this command ...
Page 523: ...53 SNMPv1 v2 v3 Commands 523 ...
Page 562: ...57 Subnet VLAN Commands 562 ...