background image

IBM Ethernet Switch c-series

Installation and User Guide

Service information: 4002-C4A, -C4B, -C5A, -C5B

GC27-2238-00

Summary of Contents for 4002-C4A

Page 1: ...IBM Ethernet Switch c series Installation and User Guide Service information 4002 C4A C4B C5A C5B GC27 2238 00 ...

Page 2: ......

Page 3: ...IBM Ethernet Switch c series Installation and User Guide Service information 4002 C4A C4B C5A C5B GC27 2238 00 ...

Page 4: ... EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states or regions do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you Order publications through your IBM representative or the IBM branch office serving your locality Copyright International B...

Page 5: ... Chapter 2 Product overview 3 Introduction 3 Product overview 3 Software features 4 Hardware features 4 B48C 4002 C4A Copper 4 B50C 4002 C5A Copper 4 B48C 4002 C4B Fiber 5 B50C 4002 C5B Fiber 5 Control features 5 Serial management interface Console port 5 LEDs for ports 5 B48C and B50C network interfaces 6 Supported optics 6 Port regions 7 Power supplies 7 AC power supplies 8 About redundant power...

Page 6: ... Installing a fiber optic module 27 Cabling a fiber optic module 28 Cleaning fiber optic modules 28 Chapter 5 Getting familiar with c series Command Line Interface CLI 29 Logging on through the CLI 29 Online help 29 Command completion 29 Scroll control 30 Line editing commands 30 Searching and filtering output from CLI commands 31 Searching and filtering output from show commands 31 Displaying lin...

Page 7: ...running configuration 51 Replacing the running configuration with the startup configuration 51 Copying a configuration file to or from a TFTP server 51 Making local copies of the startup configuration file 51 Dynamic configuration loading 52 Usage considerations 52 Preparing the configuration file 52 Loading the configuration information into the running config 54 Using SNMP to save and load confi...

Page 8: ...vi IBM Ethernet Switch c series Installation and User Guide ...

Page 9: ...er supply 13 9 Power supply installation 13 10 Front rack mount position 15 11 5 inch offset rack mount position 16 12 Mid rack mount position 17 13 Reverse rack mount position 18 14 Installing the switch in a rack 19 15 Power supply locking screws 39 16 Console port pin and signalling details 61 17 Console port pin assignments showing cable connection options to a terminal or PC 61 Copyright IBM ...

Page 10: ...viii IBM Ethernet Switch c series Installation and User Guide ...

Page 11: ... for power 39 10 Software image files 45 11 Description of software images 46 12 Code flash and boot flash information 47 13 Command syntax for upgrading monitor and boot images on the switch 50 14 Error codes messages explanations and actions 56 15 Maximum power calculations at 100 240 VAC 59 16 Physical dimensions of the switches 59 17 B48C and B50C operating environment 60 18 B48C and B50C stor...

Page 12: ...x IBM Ethernet Switch c series Installation and User Guide ...

Page 13: ...e xvi v Rack safety on page xviii Safety notices and labels When using this product observe the danger caution and attention notices contained in this guide The notices are accompanied by symbols that represent the severity of the safety condition The danger and caution notices are listed in numerical order based on their IDs which are displayed in parentheses for example D004 at the end of each n...

Page 14: ...o the cable ESD precautions Attention Many of the field replaceable units FRUs are sensitive to electrostatic discharge ESD and can potentially be damaged by improper handling Wear a wrist grounding strap connected to chassis ground if the device is plugged in or a bench ground Store all ESD sensitive components in antistatic packaging Caution notices A caution notice calls attention to a situatio...

Page 15: ... takes two persons to safely lift this part or unit C009 CAUTION This product is equipped with a 3 wire two conductors and ground power cable and plug Use this power cable with a properly grounded electrical outlet to avoid electrical shock C018 CAUTION Servicing of this product or unit is to be performed by trained service personnel only C032 Danger notices A danger notice calls attention to a si...

Page 16: ...ngerous voltage on the metal shell If any of the conditions are not as described STOP Ensure the improper voltage or impedance conditions are corrected before proceeding D003 DANGER An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the devices that attach to the system It is the responsibility of the customer to ensure that the outlet is...

Page 17: ...possible use one hand only to connect or disconnect signal cables v Never turn on any equipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instructed otherwise in the installation and configuration procedures v Connect and disconnect cables as described below...

Page 18: ...e computer room as needed to perform required service actions The customer is also responsible for using professional movers riggers in the case of equipment relocation or disposal 500 lbs 227 kg a69i0333 DANGER Heavy equipment personal injury or equipment damage might result if mishandled D006 Safety labels As an added precaution safety labels are often installed directly on products or product c...

Page 19: ...vere injury or death L004 CAUTION Hazardous energy present Voltages with hazardous energy might cause heating when shorted with metal which might result in splattered metal burns or both L005 CAUTION Hazardous moving parts nearby L008 P N 18P5850 B SJ000752 CAUTION Pinch hazard L012 Preface xvii ...

Page 20: ...ure that the outlet is correctly wired and grounded to prevent an electrical shock R001 part 1 of 2 CAUTION v Do not install a unit in a rack where the internal rack ambient temperatures will exceed the manufacturer s recommended ambient temperature for all your rack mounted devices v Do not install a unit in a rack where the air flow is compromised Ensure that air flow is not blocked or reduced o...

Page 21: ...cumentation that came with your rack cabinet for the weight of a loaded rack cabinet Verify that all door openings are at least 760 x 2030 mm 30 x 80 in Ensure that all devices shelves drawers doors and cables are secure Ensure that the four leveling pads are raised to their highest position Ensure that there is no stabilizer bracket installed on the rack cabinet during movement Do not use a ramp ...

Page 22: ...ies to your product Brocade products with no IBM equivalents are not listed in the table Note that the IBM products can be ordered with additional features while Brocade products with those additional features may be offered as separate models Table 1 Comparable IBM and Brocade products IBM product name IBM machine type IBM model HVEC model in parentheses Brief product description Brocade product ...

Page 23: ... Ethernet ports and a two port CX4 module FGS648P STK Getting help For the latest version of your product documentation visit the web at www elink ibmlink ibm com public applications publications cgibin pbi cgi Search by form number or title For more information about this and other IBM products visit the IBM web site www ibm com For support information for this product and other products see the ...

Page 24: ...n title v Form number for example GC26 1234 02 v Page numbers to which you are referring If the Reader Comment Form in the back of this manual is missing you can direct your mail to International Business Machines Corporation Information Development Department GZW 9000 South Rita Road Tucson Arizona 85744 0001 U S A When you send information to IBM you grant IBM a nonexclusive right to use or dist...

Page 25: ...k installers system administrators and resellers who will install the NetIron hardware This guide assumes a working knowledge of Layer 2 and Layer 3 switching and routing concepts Nomenclature This guide uses the following typographical conventions to show information Italic highlights the title of another publication and occasionally emphasizes a word or phrase Bold highlights a CLI command Bold ...

Page 26: ...2 IBM Ethernet Switch c series Installation and User Guide ...

Page 27: ...A Copper 48x 10 100 1000 Mbps RJ45 Ethernet ports including 4x combination 100 1000 Mbps SFP Ethernet ports v B50C 4002 C5A Copper 48x 10 100 1000 Mbps RJ45 Ethernet ports plus 2x 10 Gbps XFP Ethernet ports v B48C 4002 C4B Hybrid Fiber 48x 100 1000 Mbps SFP Ethernet ports v B50C 4002 C5B Hybrid Fiber 48x 100 1000 Mbps SFP Ethernet ports plus 2x 10 Gbps XFP Ethernet ports Product overview The c ser...

Page 28: ...grade package to apply your license and activate the features Hardware features This section describes the physical characteristics of the switches For details about physical dimensions power supply specifications and pinouts see Hardware specifications on page 59 The following figures show the front panels of the devices B48C 4002 C4A Copper The B48C 4002 C4A Copper has 48 ports of 10 100 1000 RJ...

Page 29: ...mall Form Factor Pluggable XFP MSA compliant optical transceivers Serial management interface Console port The serial management interface is present on all models and enables you to configure and manage the device using a third party terminal emulation application on a directly connected PC A straight through EIA TIA DB 9 serial cable M F ships with the device The serial management interface the ...

Page 30: ...a port to the network the fiber connectors take precedence over the copper connectors These ports support true media automatic detection meaning the device selects the fiber or copper connector based on link availability If a fiber link cannot be established the device selects the copper media 10 Gbps ports The B50C models come with 10 gigabit Ethernet ports installed The 10 gigabit Ethernet ports...

Page 31: ...optic modules provide an optical transceiver or physical medium dependent PMD interface for single or multi mode fiber that can be used with the LAN physical layer PHY and support optical monitoring capabilities Types of Brocade branded XFP transceivers for the 10 GbE ports include v Short Reach 850 nm serial pluggable XFP optic 10 Gbps up to 300 m over multi mode fiber LC connector v Long Reach 1...

Page 32: ...s For greater assurance of continued operation each power supply should be connected to a separate building circuit or power source Cooling system and fans This section describes the six cooling fans installed in these switches The B48C and B50C cooling fans pull the air from the front to the back of the device The fans in the switches include six four speed fans that operate at low speed medium s...

Page 33: ...witch B48C or B50C device with 1x AC power supply v CD ROM containing software images and the user documentation including this guide v Adjustable rack mounting ears v 6 straight through EIA TIA DB 9 serial console cable v Grounding lug General requirements To manage the system you need the following items for serial connection to the router v A management station such as a PC running a terminal e...

Page 34: ...should not be connected to a power source Installing a redundant power supply on page 12 4 Install the device in an equipment rack Installing the device on page 14 5 Once the device is physically installed plug the device into a nearby power source that adheres to the regulatory requirements outlined in this manual Powering on the system on page 19 6 Verify that the system LEDs are registering the...

Page 35: ... up It is possible to insert the supply upside down although the supply will not engage with the power backplane when upside down Attention Remove the power cord from a power supply before you install it in or remove it from the device Otherwise the power supply or the device could be damaged as a result The device can be running while a power supply is being installed or removed but the power sup...

Page 36: ...uitable for installation in Network Telecommunications facilities and locations where the NEC National Electric Code apply Installing a redundant power supply The switch base configuration includes one alternating current AC power supply All models have two power supply slots enabling you to install a second power supply for redundancy If you need to install a redundant power supply it may be easi...

Page 37: ...net48bc013 Figure 8 AC power supply net48bc014 Figure 9 Power supply installation Chapter 3 Installation 13 ...

Page 38: ...n agency approved crimped connector provided with the chassis attached to one end with the other end attached to building ground The connector must be crimped with the proper tool allowing it to be connected to both ground screws on the enclosure Before crimping the ground wire into the provided ground lug insure the bare copper wire has been cleaned and antioxidant is applied to the bare wire Ins...

Page 39: ...net48bc017 Figure 10 Front rack mount position Chapter 3 Installation 15 ...

Page 40: ...net48bc018 Figure 11 5 inch offset rack mount position 16 IBM Ethernet Switch c series Installation and User Guide ...

Page 41: ...net48bc019 Figure 12 Mid rack mount position Chapter 3 Installation 17 ...

Page 42: ...hers must be used to prevent rotation of the lug You will need the following tools for installation v 2 Phillips head screwdriver v It will take between 12 24 screws to mount the device to the rack Installation steps 1 Mount the device in the rack as illustrated in Figure 14 on page 19 net48bc020 Figure 13 Reverse rack mount position 18 IBM Ethernet Switch c series Installation and User Guide ...

Page 43: ...vered Attention Never leave tools inside the device 2 Remove the power cord from the shipping package 3 Attach the AC power cable to the AC connector on the rear panel 4 Insert the power cable plug into a 115V 120V outlet Note To turn the system off simply unplug the power cord s Note The socket should be installed near the equipment and should be easily accessible net48bc021 Figure 14 Installing ...

Page 44: ...to a power source and verifying that it passes its self test If your device has more than one power supply installed repeat this procedure for each power supply 1 Connect the power cord supplied with the device to the power connector on the power supply on the rear of the device 2 Insert the other end into a properly grounded electrical outlet 3 Verify that the LED for each power supply is a solid...

Page 45: ... the software automatically generates a Syslog message and SNMP trap if a status change occurs Attaching a PC or terminal To assign an IP address you must have access to the Command Line Interface CLI The CLI is a text based interface that can be accessed through a direct serial connection to the device and through Telnet connections The CLI is described in detail in the Brocade Switch and Router ...

Page 46: ...system name See the Configuration Guide If you do not see one of these prompts 1 Make sure the cable is securely connected to your PC and to the system 2 Check the settings in your terminal emulation program In addition to the session settings listed above make sure the terminal emulation session is running on the same serial port you attached to the system The EIA TIA 232 serial communication por...

Page 47: ...s 1 or 2 save the system configuration to flash memory and clear caches at this level v CONFIG The configuration level This level lets you configure the system s IP address and configure routing features To access the CONFIG mode you must already be logged into the Privileged level of the EXEC mode You can set the following levels of Enable passwords v Super User Allows complete read and write acc...

Page 48: ...face Single 10 100 1000 Mbps Ethernet management port Out of band Any interface over which user packets are routed Any network interface port In band Any virtual interface over which user packets are routed Any interface port In band Loopback interface In band This section describes the following v The B48C and B50C support of sub net masks v How to assign an IP address to a management interface v...

Page 49: ...configure terminal Privileged EXEC Level NetIron config Global CONFIG Level 4 Configure the IP address and mask for the management interface by entering the following commands NetIron config interface management 1 NetIron config if mgmt 1 ip address 10 0 1 1 255 255 255 0 Syntax enable password Syntax configure terminal Syntax interface management 1 Syntax no ip address ip addr ip mask or Syntax n...

Page 50: ...ddr ip mask secondary or Syntax no ip address ip addr mask bits secondary Use the secondary parameter if you have already configured an IP address within the same sub net on the interface Enabling and disabling the interfaces By default all interfaces on the c series switches are disabled To enable an interface you must enter the enable command at the appropriate interface configuration level of t...

Page 51: ...witch You can connect a c series switch to another Ethernet network device To connect a switch to another network device you must do the following v Install the fiber optic modules if required v Cable the modules with either copper cable or fiber optic cable as required Installing a fiber optic module To connect a switch to another network device using a fiber port do the following v Install a fib...

Page 52: ...e tabs lock into place Cleaning fiber optic modules To avoid problems with the connection between the fiber optic module port and the fiber cable connector IBM strongly recommends cleaning both connectors before making this connection In particular dust can accumulate in either connector and cause problems such as reducing the optic launch power When not using a fiber optic module port connector m...

Page 53: ...to the device To save the changes across software reloads and system resets you need to save them to the system config file The CONFIG level contains sub levels for individual ports for VLANs for routing protocols and other configuration areas Note By default any user who can open a direct or Telnet connection to the switch can access all these CLI levels To secure access you can configure Enable ...

Page 54: ...nds The CLI supports the following line editing commands To enter a line editing command use the CTRL key combination for the command by pressing and holding the CTRL key then pressing the letter associated with the command Table 7 CLI line editing commands Ctrl Key Combination Description Ctrl A Moves to the first character on the command line Ctrl B Moves the cursor back one character Ctrl C Esc...

Page 55: ...used with regular expressions Displaying lines containing a specified string The following command filters the output of the show interface command for port 3 1 so it displays only lines containing the word Internet This command can be used to display the IP address of the interface NetIron show interface e 3 1 include Internet Internet address is 192 168 1 11 24 MTU 1518 bytes encapsulation ether...

Page 56: ...ver flash image cd Change current working directory chdir Change current working directory clear Clear table statistics keys clock Set clock configure Enter configuration mode copy Copy between flash tftp config code cp Copy file commands debug Enable debugging functions see also undebug delete Delete file on flash dir List files dm test commands dot1x 802 1X erase Erase image configuration files ...

Page 57: ...o flash or terminal As with the commands for filtering output from show commands the search string is a regular expression consisting of a single character or string of characters You can use special characters to construct complex regular expressions See the next section for information on special characters used with regular expressions Using special characters in regular expressions You use a r...

Page 58: ...nter Ctrl V and then type a question mark the question mark is inserted into the command line allowing you to use it as part of a regular expression A caret when not used within brackets matches on the beginning of an input string For example the following regular expression matches output that begins with deg deg A dollar sign matches on the end of an input string For example the following regula...

Page 59: ...he beginning and ending of a range of characters A match occurs if any of the characters within the range is present See the example above A vertical bar separates two alternative values or sets of values The output can match one or the other value For example the following regular expression matches output that contains either abc or defg abc defg Parentheses allow you to create complex expressio...

Page 60: ...36 IBM Ethernet Switch c series Installation and User Guide ...

Page 61: ...ollowing topics v Installation precautions and warnings v Determining which power supply has failed if necessary v Replacing a power supply DANGER Power supplies are hot swappable However IBM recommends that you disconnect the power supply from AC power before installing or removing the supply The device can be running while a power supply is being installed or removed but the power supply itself ...

Page 62: ...e slots the power supply installed in that particular slot has failed AC power supplies Use the following procedures for AC power supplies in c series switches You will need the following tool to perform this procedure v 2 Phillips head screwdriver Removing an AC power supply 1 Unplug the power supply from the power source 2 Disconnect the power cord from the power supply 3 If necessary remove the...

Page 63: ...e supply in place 6 Connect the power cord to the power supply 7 Connect the plug end of the power cord into an outlet Verifying proper operation To verify the proper operation of the power supply after power on you can observe the LEDs on the power supply After the device powers on you can observe the LEDs on the front of the device to verify that it initialized successfully Table 9 outlines the ...

Page 64: ...ified power supply slot and the status of the power supply which can be one of the following NetIron show chassis FANS Metro fan tray fan 1 Status OK Speed MED 75 Metro fan tray fan 2 Status OK Speed MED 75 Metro fan tray fan 3 Status OK Speed MED 75 Metro fan tray fan 4 Status OK Speed MED 75 Metro fan tray fan 5 Status OK Speed MED 75 Metro fan tray fan 6 Status OK Speed MED 75 NetIron CES 2024C...

Page 65: ...tor v The protective covering that you removed from the fiber optic module when you initially installed the module To remove a fiber optic module from a gigabit Ethernet or 10 gigabit Ethernet port do the following 1 Put on the ESD wrist strap and ground yourself by attaching the clip end to a metal surface such as an equipment rack 2 Disconnect the fiber cable connector from the port connector 3 ...

Page 66: ...ng a fiber optic module IBM strongly recommends cleaning the cable connectors and the port connectors See Cleaning the fiber optic connectors 3 Gently insert the cable connector s a tab on each connector should face upward into the port connector s until the tabs lock into place 4 Observe the link and active LEDs to determine if the network connections are functioning properly CAUTION The intra bu...

Page 67: ... software upgrade instructions see the release notes and the Configuration Guide Note The device must have an IP address If the device does not already have an IP address configure one by entering the ip address ip addr ip mask command at the global CONFIG level of the CLI Chapter 6 Maintaining the hardware 43 ...

Page 68: ...44 IBM Ethernet Switch c series Installation and User Guide ...

Page 69: ...or upgrading have been changed as described in the following sections v Description of the software images required on page 46 This subsection describes each of the images required to operate the B48C and B50C v Upgrading the multi service IronWare software on page 46 This subsection describes the procedures required for your software upgrade depending upon the version you are upgrading from or to...

Page 70: ...de you will usually only need to upgrade Multi Service IronWare image The Boot and Monitor images will only need to be upgraded as specifically directed in the relevant release notes The steps for this upgrade include the following 1 Determine the versions of the software images currently installed and running on the switch 2 Upgrade the device s Multi Service IronWare Image 3 Reboot the switch In...

Page 71: ...ed in the primary or secondary location in the code flash The image must be ce xxxxx The actual image name depends on the version of software you have running on your switch The output displays the following information about the image v Version 3 8 00Txxy indicates the image version number The Txxy is used by support for record keeping The xx indicates the hardware type while the y indicates the ...

Page 72: ...rsion command NetIron config show version HW NetIron CES ME_PREM Backplane Serial PR09080002 Part 36001 00J Boot Version 3 8 0T185 Copyright c 1996 2007 Foundry Networks Inc Compiled on Aug 20 2008 at 03 13 44 labeled as ceb03800 347473 bytes from boot flash Monitor Version 3 8 0T185 Copyright c 1996 2007 Foundry Networks Inc Compiled on Aug 20 2008 at 03 13 44 labeled as ceb03800 347473 bytes fro...

Page 73: ...TRL X or type exit to disconnect it LP 1 en No password has been assigned yet LP 1 Syntax rconsole slot number The slot number parameter specifies the chassis slot number of the virtual interface module to which you want to open an rconsole session For the B48C and B50C switches this should always be 1 Syntax enable Syntax exit Syntax Ctrl X Upgrading the multi service IronWare image To upgrade th...

Page 74: ...hat the new monitor and boot images have been successfully copied to flash or slot 1 or 2 by entering one of the following commands at the Privileged EXEC level of the CLI v show flash v dir path name Check for the boot image monitor image and the date and time at which the new images were built 4 If you want to upgrade other software images go to the appropriate upgrade section for information If...

Page 75: ... or n Enter y and press the Enter key Copying a configuration file to or from a TFTP server To copy the startup config or running config file to or from a TFTP server use one of the following methods Note You can name the configuration file when you copy it to a TFTP server However when you copy a configuration file from the server to the switch the file is always copied as startup config or runni...

Page 76: ...ort Preparing the configuration file A configuration file that you create must follow the same syntax rules as the startup config file the device creates v The configuration file is a script containing CLI configuration commands The CLI reacts to each command entered from the file in the same way the CLI reacts to the command if you enter it For example if the command results in an error message o...

Page 77: ...and is a spanning tree command whose syntax is valid at the global CONFIG level as well as the interface configuration level then the software applies the command globally Here is an example The configuration file contains these commands interface ethernet1 2 no spanning tree The CLI responds like this NetIron config interface ethernet 1 2 Error cannot configure secondary ports of a trunk NetIron ...

Page 78: ...CLI no snmp server pw check This command disables password checking for SNMP set requests If a third party SNMP management application does not add a password to the password field when it sends SNMP set requests to the switch by default the switch rejects the request 3 From a management station send the following SNMP PDU to the agent SnmpSet 1 3 6 1 4 1 1191 1 1 2 1 5 0 TFTP IP address 1 3 6 1 4...

Page 79: ...can set the device clock manually Reloading at a specific time To schedule a system reload for a specific time use one of the following methods To schedule a system reload from the primary flash module for 6 00 00 AM January 19 2006 enter the following command at the Privileged EXEC level of the CLI NetIron reload at 06 00 00 01 19 06 Syntax reload at hh mm ss mm dd yy primary secondary hh mm ss i...

Page 80: ...unning 6 TFTP out of buffer space The file is larger than the amount of space on the device or TFTP server If you are copying an image file to flash first copy the other image to your TFTP server then delete it from flash Use the erase flash CLI command at the Privileged EXEC level to erase the image in the flash If you are copying a configuration file to flash edit the file to remove unneeded inf...

Page 81: ...or The specific error message describes the error Correct the error then retry the transfer 17 TFTP remote no such file 18 TFTP remote access violation 19 TFTP remote disk full 20 TFTP remote illegal operation 21 TFTP remote unknown transfer ID 22 TFTP remote file already exists 23 TFTP remote no such user Chapter 7 Upgrading software images and configuration files 57 ...

Page 82: ...58 IBM Ethernet Switch c series Installation and User Guide ...

Page 83: ...switches Table 15 provides the maximum power calculations for the B48C and B50C Table 15 Maximum power calculations at 100 240 VAC Device model Amps Watts BTUs per hour B48C 4002 C4A Copper 2 05 205 700 B50C 4002 C5A Copper 2 55 255 870 B48C 4002 C4B Hybrid Fiber 3 45 245 836 B50C 4002 C5B Hybrid Fiber 3 90 295 1007 Physical dimensions Table 16 provides the physical dimensions for the B48C and B50...

Page 84: ... LFM v Fan operating noise Based on ISO 7779 60 dB A Port specifications This section provides pin assignments for the following ports v Device s console port serial connector v Device s management port RJ 45 unshielded twisted pair UTP connector CAUTION The intra building port s of the equipment or subassembly is suitable for connection to intra building or unexposed wiring or cabling only The in...

Page 85: ...J 45 UTP connector Table 19 describes the connector s pin assignments Table 19 Management port pin assignments Pin number MDI X ports 1 TD 1 5 9 6 Pin Assignment DB 9 male Pin Number 1 2 3 4 5 6 7 8 9 Switch Signal Reserved TXD output RXD input GND CTS input RTS output Reserved Reserved Reserved Figure 16 Console port pin and signalling details 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9...

Page 86: ...s continued Pin number MDI X ports 2 TD 3 RD 4 Not used 10BaseT CMT 100BaseTX 5 Not used 10BaseT CMT 100BaseTX 6 RD 7 Not used 10BaseT CMT 100BaseTX 8 Not used 10BaseT CMT 100BaseTX 62 IBM Ethernet Switch c series Installation and User Guide ...

Page 87: ...HINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer of express or implied warranties in certain transactions therefore this statement may not apply to you This information could include t...

Page 88: ...liers of those products If you are viewing this information in softcopy the photographs and color illustrations may not appear Trademarks IBM the IBM logo and ibm com are trademarks or registered trademarks of International Business Machines Corporation in the United States other countries or both A complete and current list of other IBM trademarks is available on the Web at http www ibm com legal...

Page 89: ...ileged EXEC level 23 scroll control 30 securing access 23 Command completion CLI 29 comments sending xxii CONFIG Level 23 Configuration displaying 50 erasing 55 saving 50 Connector console 21 Console attaching 21 Conventions manual 1 D danger notices xiii definitions xiii examples xiii Desktop installation 14 Dimensions 59 documents Brocade xx product xx E Enable password assigning 23 environmenta...

Page 90: ...ty xviii rack relocation safety xix rack safety xviii reader comment form xxii Redundant Power Supply Caution 10 Reload scheduled 55 Running config file 50 S safety xi labels xi xvi examples xvi notices xi rack xviii rack installation xviii rack relocation xix safety labels xvi safety notices xi safety rack xviii safety rack installation xviii safety rack relocation xix Scheduled reload 55 Scroll ...

Page 91: ...nd information about products and prices please contact your IBM branch office your IBM business partner or your authorized remarketer When you send comments to IBM you grant IBM a nonexclusive right to use or distribute your comments in any way it believes appropriate without incurring any obligation to you IBM or any other organizations will only use the personal information that you supply to c...

Page 92: ... Development Dept GZW 9000 South Rita Road Tucson AZ U S A 85744 0001 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

Page 93: ......

Page 94: ... Part Number 45W3139 Printed in USA GC27 2238 00 1P P N 45W3139 80218 001 ...

Reviews: