Operating environment
Table 17 provides the operating environment specifications for the B48C and B50C.
Table 17. B48C and B50C operating environment
Operating temperature
Relative humidity
Operating altitude
0° C to 40° C (32° F to 104°
F)
5% to 90%, at 40° C (104°
F), non-condensing
10,000 ft
Storage environment
Table 18 provides the storage environment specifications for the B48C and B50C.
Table 18. B48C and B50C storage environment
Storage temperature
Storage humidity
Storage altitude
-25° C to 70° C (-13° F to
158° F)
95% maximum relative
humidity, non-conducing
15,000 ft (4,500 m) maximum
Cooling
The cooling fans cool the CPU, main memory, and voltage regulators. The fans use
either a push or pull configuration to move the air from the front to the device to the
back of the device.
v
Total cooling capacity: 350 watts
v
Total air flow: 267 LFM
v
Fan operating noise:
– Based on ISO 7779
– < 60 dB-A
Port specifications
This section provides pin assignments for the following ports:
v
Device’s console port (serial connector)
v
Device’s management port (RJ-45 unshielded twisted pair (UTP) connector)
CAUTION:
The intra-building port(s) of the equipment or subassembly is suitable for
connection to intra-building or unexposed wiring or cabling only. The
intra-building port(s) of the equipment or subassembly MUST NOT be
metallically connected to interfaces that connect to the OSP or its wiring.
These interfaces are designed for use as intra-building interfaces only (Type 2
or Type 4 ports as described in GR-1089-CORE, Issue 4) and require isolation
from the exposed OSP cabling. The addition of Primary Protectors is not
sufficient protection in order to connect these interfaces metallically to OSP
wiring.
Console port pin assignments
The console port is a standard male DB-9 connector, as shown in Figure 16 on
page 61.
60
IBM Ethernet Switch c-series Installation and User Guide
Summary of Contents for 4002-C4A
Page 2: ......
Page 8: ...vi IBM Ethernet Switch c series Installation and User Guide ...
Page 10: ...viii IBM Ethernet Switch c series Installation and User Guide ...
Page 12: ...x IBM Ethernet Switch c series Installation and User Guide ...
Page 26: ...2 IBM Ethernet Switch c series Installation and User Guide ...
Page 39: ...net48bc017 Figure 10 Front rack mount position Chapter 3 Installation 15 ...
Page 41: ...net48bc019 Figure 12 Mid rack mount position Chapter 3 Installation 17 ...
Page 60: ...36 IBM Ethernet Switch c series Installation and User Guide ...
Page 68: ...44 IBM Ethernet Switch c series Installation and User Guide ...
Page 82: ...58 IBM Ethernet Switch c series Installation and User Guide ...
Page 93: ......
Page 94: ... Part Number 45W3139 Printed in USA GC27 2238 00 1P P N 45W3139 80218 001 ...