Table 5. LEDs for power and fans (continued)
LED
Position
State
Meaning
PS1 (labeled p1)
Left side of front
panel
Amber
Power supply 1 is installed, but
not connected or a fault is
detected.
Green steady
Power supply 1 is installed and
is functioning normally.
Green blinking
Power supply 1 has input
power, but is not enabled and
has no output power.
Off
Power supply 1 is not installed
or is not providing power.
PS2 (labeled p2)
Left side of front
panel
Amber
Power supply 2 is installed, but
not connected or a fault is
detected.
Green steady
Power supply 2 is installed and
is functioning normally.
Green blinking
Power supply 2 has input
power, but is not enabled and
has no output power.
Off
Power supply 2 is not installed
or is not providing power.
The software regularly polls the hardware for power status information. You can
display the status information from any management session. In addition, the
software automatically generates a Syslog message and SNMP trap if a status
change occurs.
Attaching a PC or terminal
To assign an IP address, you must have access to the
Command Line Interface
(CLI)
. The CLI is a text-based interface that can be accessed through a direct serial
connection to the device and through Telnet connections. The CLI is described in
detail in the
Brocade Switch and Router Command Line Interface Reference
.
You need to assign an IP address using the CLI. You can access the CLI by
attaching a serial cable to the Console port. After you assign an IP address, you
can access the system through Telnet, the Web management interface, or IronView
Network Manager.
To attach a management station using the serial port:
1. Connect a PC or terminal to the serial port of the system using a
straight-through cable. The serial port has a male DB-9 connector.
Note:
You need to run a terminal emulation program on the PC.
2. Open the terminal emulation program and set the session parameters as
follows:
v
Baud: 9600 bps
v
Data bits: 8
v
Parity: None
v
Stop bits: 1
Chapter 3. Installation
21
Summary of Contents for 4002-C4A
Page 2: ......
Page 8: ...vi IBM Ethernet Switch c series Installation and User Guide ...
Page 10: ...viii IBM Ethernet Switch c series Installation and User Guide ...
Page 12: ...x IBM Ethernet Switch c series Installation and User Guide ...
Page 26: ...2 IBM Ethernet Switch c series Installation and User Guide ...
Page 39: ...net48bc017 Figure 10 Front rack mount position Chapter 3 Installation 15 ...
Page 41: ...net48bc019 Figure 12 Mid rack mount position Chapter 3 Installation 17 ...
Page 60: ...36 IBM Ethernet Switch c series Installation and User Guide ...
Page 68: ...44 IBM Ethernet Switch c series Installation and User Guide ...
Page 82: ...58 IBM Ethernet Switch c series Installation and User Guide ...
Page 93: ......
Page 94: ... Part Number 45W3139 Printed in USA GC27 2238 00 1P P N 45W3139 80218 001 ...