5 Port 100BASE-TX Industrial ECO Switch 

Mounting, Installation and Handling 

Version 1.2.0, valid from FW/HW Version 01/06 

 
 

 

Содержание ETHERNET Accessories 852 852-0111

Страница 1: ...Manual WAGO ETHERNET Accessories 852 852 0111 5 Port 100BASE TX Industrial ECO Switch Mounting Installation and Handling Version 1 2 0 valid from FW HW Version 01 06 ...

Страница 2: ...45 55 Fax 49 0 571 8 87 84 45 55 E Mail support wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However as errors can never be fully excluded we always appreciate any information or suggestions for improving the documentation E Mail documentation wago com We wish to point out that the software and hardware terms as well as the tradema...

Страница 3: ...es 11 2 2 Safety Advice Precautions 12 2 3 Special Use Conditions for ETHERNET Devices 14 3 General 15 3 1 Scope of Supply 15 3 2 Industrial ETHERNET Technology 15 3 3 Switching Technology 15 3 4 Auto Negotiation 15 3 5 Functioning of Switches 15 3 6 Port Speed Duplex Mode 16 4 Device Description 17 4 1 View 18 4 1 1 Front view 18 4 1 2 TOP View 19 4 2 Connectors 20 4 2 1 Power Supply PWR 20 4 2 2...

Страница 4: ...00BASE TX Industrial ECO Switch Manual Version 1 2 0 valid from FW HW Version 01 06 6 Connect Devices 30 6 1 1 Power Supply 30 7 Accessories 31 8 Appendix 32 8 1 RJ 45 Cables 100BASE TX 32 8 2 Drilling Template for Screw Mounting 33 List of Figures 34 List of Tables 35 ...

Страница 5: ...ry 1 1 Validity of this Documentation This documentation is only applicable to WAGO ETHERNET accessory products 5 Port 100BASE TX Industrial ECO Switch 852 0111 This documentation is only applicable from FW HW Version 01 06 1 2 Copyright This Manual including all figures and illustrations is copyright protected Any further use of this Manual by third parties that violate pertinent copyright provis...

Страница 6: ...rsonal Injury Indicates a moderate risk potentially hazardous situation which if not avoided could result in death or serious injury Personal Injury Indicates a low risk potentially hazardous situation which if not avoided may result in minor or moderate injury Damage to Property Indicates a potentially hazardous situation which if not avoided may result in damage to property Damage to Property Ca...

Страница 7: ...f Figures 7 852 0111 5 Port 100BASE TX Industrial ECO Switch Manual Version 1 2 0 valid from FW HW Version 01 06 Additional Information Refers to additional information which is not an integral part of this documentation e g the Internet ...

Страница 8: ...mes of paths and data files are marked in italic type e g C Program Files WAGO Software Menu Menu items are marked in bold letters e g Save A greater than sign between two names means the selection of a menu item from a menu e g File New Input Designation of input or optional fields are marked in bold letters e g Start of measurement range Value Input or selective values are marked in inverted com...

Страница 9: ...out by electrical specialists with sufficient knowledge in automation The specialists must be familiar with the current norms and guidelines for the devices and automated environments All changes to the controller should always be carried out by qualified personnel with sufficient sufficient skills in PLC programming 2 1 3 Proper Use of the Industrial Switches The device is designed for the IP30 p...

Страница 10: ... 100BASE TX Industrial ECO Switch Manual Version 1 2 0 valid from FW HW Version 01 06 Further details are given in the contractual agreements Please send your request for modified and new hardware or software configurations directly to WAGO Kontakttechnik GmbH Co KG ...

Страница 11: ...air please observe the accident prevention regulations of your machine e g DGUV Regulation Electrical Installations and Equipment Emergency stop functions and equipment must not be deactivated or otherwise made ineffective See relevant standards e g DIN EN 418 Your installation must be equipped in accordance to the EMC guidelines so electromagnetic interferences can be eliminated Please observe th...

Страница 12: ... lockable housings cabinets or electrical operation rooms Access must be limited to authorized qualified staff having the appropriate key or tool Ensure a standard connection To minimize any hazardous situations resulting in personal injury or to avoid failures in your system the data and power supply lines shall be installed according to standards with careful attention given to ensuring the corr...

Страница 13: ...d materials are imperative for handling devices modules Clean only with permitted materials Clean housing and soiled contacts with propanol Do not use any contact spray Do not use any contact spray The spray may impair contact area functionality in connection with contamination Do not reverse the polarity of connection lines Avoid reverse polarity of data and power supply lines as this may damage ...

Страница 14: ...nts and control networks behind a firewall Limit physical and electronic access to all automation components to authorized personnel only Change the default passwords before first use This will reduce the risk of unauthorized access to your system Regularly change the passwords used This will reduce the risk of unauthorized access to your system If remote access to control components and control n...

Страница 15: ... full duplex The targeted use of switching technology can increase real time capability because the peer to peer connection prevents collisions in network communication 3 4 Auto Negotiation The Industrial Switch s 10 100Mbps switched RJ 45 ports auto negotiates with connected devices to determine the fastest data transmission rate supported by both devices This helps make the Switch a plug and pla...

Страница 16: ...nment table for a destination address If a destination address answers the assignment table is complemented with this destination address as well as the associated port 3 6 Port Speed Duplex Mode After a cable is plugged into a specific port the system uses auto negotiation to determine the transmission mode for the new twisted pair connection If the connected device does not support auto negotiat...

Страница 17: ...e that the buffer is effectively allocated for each port while controlling the data flow between the transmit and receive nodes to guarantee against all possible packet loss Other key features are Five 5 10 100BASE TX Ports Comprehensive front panel diagnostic LEDs Supports Auto MDI MDI X Full half duplex transfer modes for each port Wide supply voltage range 18 30 V Store and forward switching me...

Страница 18: ...strial ECO Switch Manual Version 1 2 0 valid from FW HW Version 01 06 4 1 View 4 1 1 Front view Figure 1 Front view of Industrial ECO Switch Table 3 Legend for Front view of industrial ECO switch figure Position Description 1 TX port 100 Mbps LED 2 TX port LNK ACT LED 3 TX ports 5 ...

Страница 19: ... Switch Manual Version 1 2 0 valid from FW HW Version 01 06 4 1 2 TOP View Figure 2 Top view of Industrial ECO Switch Table 4 Legend for Top view of the industrial ECO switch figure Position Description 1 Terminal block male connector for power input PWR 2 Primary power LED 3 Grounding Screw ...

Страница 20: ...s the following pin assignment Figure 3 Power supply PWR port Table 5 Legend for Power supply PWR port figure Pin Description Description PWR Primary DC input PWR Primary DC input Y GND Ground potential functional earth Damage to Property Caused by Electrostatic Discharge ESD Industrial ECO switch for DC operation Power supply is provided via an external direct current power source As the industri...

Страница 21: ... TX ports support network speeds of either 10 Mbit s or 100 Mbit s and can operate in half and full duplex transfer modes The ports also offer automatic MDI MDI X crossover detection that gives true plug and play capability just plug the network cables into the ports and the ports will adjust according to the end node devices The following are the recommended cables for the RJ 45 connectors 100 m ...

Страница 22: ...for the appropriate port You can see the status of the industrial ECO switch at a quick glance of the power supply LED while the network LEDs provide information about the connection actions 4 3 1 Power Supply LED Figure 5 Power supply LED Table 6 Legend for Power supply LED figure LED Name Status Description PWR Primary Power LED Green The industrial ECO switch uses the primary power supply OFF T...

Страница 23: ...e 7 Legend for Network LEDs figure LED Name Status Description 100 TX port 100 Mbps LED 1 LED for each port Green Port operating at 100 Mps 1 LED for each port OFF Port operating at below 100 Mps LNK ACT TX port LNK ACT LED 1 LED for each port Green Illuminated when connectors are attached 1 LED for each port Green flashing Data traffic passing through port OFF No valid link established on port ...

Страница 24: ...l mounting 109 2 mm Carrier rail mounting 109 2 mm Weight 145 g Mounting Wall mounting horizontal or vertical or mounting on a carrier rail Protection type IP30 4 4 2 Power Supply Table 9 Technical data supply Supply voltage 18 30 VDC Power consumption max 3 W 4 4 3 Communication Table 10 Technical data communication Ports 5 x 10 100BASE TX RJ 45 Standards IEEE 802 3 10BASE T IEEE 802 3u 100BASE T...

Страница 25: ...operation DNV GL Temperature class D 25 C 70 C Surrounding air temperature operation UL 40 C 60 C Surrounding air temperature storage 40 C 80 C Relative humidity without condensation 95 Vibration resistance Acc to IEC 60068 2 6 Shock resistance Acc to IEC 60068 2 27 EMC 1 immunity to interference Acc to EN 61000 6 2 EMC 1 Emission of interference Acc to EN 61000 6 4 Standard Compass Safe Distance ...

Страница 26: ...0BASE TX Industrial ECO Switch 852 0111 Conformity Marking UL508 The following ship approvals have been granted for the WAGO ETHERNET accessory product 5 Port 100BASE TX Industrial ECO Switch 852 0111 DNV GL Temperature D Humidity B Vibration C EMC B Enclosure A The DNV GL Marine Type Approval is only valid if using the 852 9101 Carrier Rail Adapter in conjunction with an ETHERNET Switch This adap...

Страница 27: ...rackets at the back of the industrial ECO switch to a carrier rail to protect the industrial ECO switch from falling Make sure that the heat output from the industrial ECO switch and ventilation around it is adequate Do not place any heavy objects on the industrial ECO switch 5 2 Installation on a Carrier Rail The carrier rail must optimally support the EMC measures integrated into the system and ...

Страница 28: ...28 List of Figures WAGO ETHERNET Accessories 852 852 0111 5 Port 100BASE TX Industrial ECO Switch Manual Version 1 2 0 valid from FW HW Version 01 06 Figure 8 Removing the device from the carrier rail ...

Страница 29: ... FW HW Version 01 06 5 4 Screw Mounting The industrial ECO switch can be mounted vertically or horizontally directly on an even surface using the boreholes on the side of the device The surface must be able to bear at least 1 5 kg for the industrial ECO switch Use the drilling template given in the appendix to mark the boreholes ...

Страница 30: ...onductors To connect or disconnect the conductors actuate the spring directly in the female connector using a screwdriver or an operating tool and insert or remove the conductor 2 Plug the female connector into the male connector of the switch if it has not already been plugged in 3 Connect a suitable grounding conductor to the grounding lug on the top of the industrial ECO switch Important note T...

Страница 31: ...al ECO Switch Manual Version 1 2 0 valid from FW HW Version 01 06 7 Accessories Table 13 Accessories Description Item Number Carrier Rail Adapter 852 9101 The 852 9101 Carrier Rail Adapter is required for Industrial ECO Switch 852 111 installations that comply with the DNV GL standard ...

Страница 32: ...follows Table 14 RJ 45 Cables Contact Description Pair Color 1 TD 2 White Orange 2 TD 2 Orange 3 RX 3 White Green 4 N A 1 Blue 5 N A 1 White Blue 6 RX 3 Green 7 N A 4 White Brown 8 N A 4 Brown Table 15 Cable Configuration Application Cable Type Application Switch to switch or network adapter Straight through cable Switch Hub End 1 1 2 2 3 3 6 6 Terminal device to switch Crossover cable Switch Conv...

Страница 33: ...ch Manual Version 1 2 0 valid from FW HW Version 01 06 8 2 Drilling Template for Screw Mounting The industrial ECO switch can be mounted vertically or horizontally using the boreholes on the side of the device Use the drilling template shown below to mark the boreholes Figure 9 Drilling template ...

Страница 34: ... List of Figures Figure 1 Front view of Industrial ECO Switch 18 Figure 2 Top view of Industrial ECO Switch 19 Figure 3 Power supply PWR port 20 Figure 4 10 100BASE TX 21 Figure 5 Power supply LED 22 Figure 6 Network LEDs 23 Figure 7 Snapping onto the carrier rail 27 Figure 8 Removing the device from the carrier rail 28 Figure 9 Drilling template 33 ...

Страница 35: ... Table 4 Legend for Top view of the industrial ECO switch figure 19 Table 5 Legend for Power supply PWR port figure 20 Table 6 Legend for Power supply LED figure 22 Table 7 Legend for Network LEDs figure 23 Table 8 Technical data device data 24 Table 9 Technical data supply 24 Table 10 Technical data communication 24 Table 11 Technical Data LEDs 24 Table 12 Technical data environmental conditions ...

Страница 36: ......

Страница 37: ...WAGO ETHERNET Accessories 852 37 852 0111 5 Port 100BASE TX Industrial ECO Switch Manual Version 1 2 0 valid from FW HW Version 01 06 ...

Страница 38: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastraße 27 D 32423 Minden Phone 49 571 887 0 Fax 49 571 887 844169 E Mail info wago com Internet www wago com ...