![NXP Semiconductors MKL27Z128VFM4 Reference Manual Download Page 706](http://html1.mh-extra.com/html/nxp-semiconductors/mkl27z128vfm4/mkl27z128vfm4_reference-manual_1721847706.webp)
UARTx_WP7816A_T1 field descriptions
Field
Description
BWI_H
Block Wait Time Integer High (C7816[TTYPE] = 1)
Used to calculate the value used for the BWT counter. This register field provides the most significant byte
of the 16 bit Block Wait Time Integer field BWI formed by {WP7816A_T1[BWI_H], WP7816B_T1[BWI_L]}.
The value of BWI = 0 is invalid and should not be programmed. This value is used only when
C7816[TTYPE] = 1. See
Wait time and guard time parameters
38.4.25 UART 7816 Wait Parameter Register B (UARTx_WP7816B_T0)
The WP7816B_T0 register contains constants used in the generation of various wait time
counters. To save register space, this register is used differently when C7816[TTYPE] =
0 and C7816[TTYPE] = 1. This register may be read at any time. This register must be
written to only when C7816[ISO_7816E] is not set.
Address: 4006_C000h base + 3Dh offset = 4006_C03Dh
Bit
7
6
5
4
3
2
1
0
Read
Write
Reset
0
0
0
1
0
1
0
0
UARTx_WP7816B_T0 field descriptions
Field
Description
WI_L
Wait Time Integer Low (C7816[TTYPE] = 0)
Used to calculate the value used for the WT counter. This register field provides the least significant byte
of the 16 bit Wait Time Integer field WI formed by {WP7816A_T0[WI_H], WP7816B_T0[WI_L]} . The value
of WI = 0 is invalid and must not be programmed. This value is used only when C7816[TTYPE] = 0. See
Wait time and guard time parameters
38.4.26 UART 7816 Wait Parameter Register B (UARTx_WP7816B_T1)
The WP7816B_T1 register contains constants used in the generation of various wait time
counters. To save register space, this register is used differently when C7816[TTYPE] =
0 and C7816[TTYPE] = 1. This register may be read at any time. This register must be
written to only when C7816[ISO_7816E] is not set.
Address: 4006_C000h base + 3Dh offset = 4006_C03Dh
Bit
7
6
5
4
3
2
1
0
Read
Write
Reset
0
0
0
1
0
1
0
0
Memory map and registers