DDR2(+LP) Compliance Testing Methods of Implementation
145
Differential Signals AC Input Parameters Tests
10
6 Select the Speed Grade options. For Differential Signals AC Input Parameters Tests that support
DDR2, you can select any speed grade within the selection. To select a LPDDR2 Speed Grade (for
tests that support LPDDR2), check the Low Power box.
7 Type in or select the Device Identifier as well as User Description from the drop-down list. Enter
your comments in the Comments text box.
8 Click the Select Tests tab and check the tests you want to run. Check the parent node or group to
check all the available tests within the group.
9 Follow the DDR2(+LP) Test application’s task flow to set up the configuration options, run the
tests and view the tests results.
Figure 21
Selecting Differential Signals AC Input Parameters Tests