DDR2(+LP) Compliance Testing Methods of Implementation
197
Clock Timing (CT) Tests
14
PASS Condition
The measured time interval between the data strobe access output and rising edge of the clock
should be within the specification limit.
Measurement Algorithm
1 Pre-condition the oscilloscope setting.
2 Acquire and split read and write burst of the acquired signal.
3 Take the first valid READ burst found.
4 Find all valid rising and falling DQS crossings at Vref in the said burst.
5 For all DQS crossings found, locate the nearest rising Clock crossing at 0V.
6 Take the time difference from DQS crossing to the corresponding Clock crossing as the tDQSCK
7 Determine the worst result from the set of tDQSCK measurements.
8 Compare the test result against the compliance test limit.