DDR2(+LP) Compliance Testing Methods of Implementation
5
DDR2(+LP) Compliance Test Application — At A Glance
The Keysight D9020DDRC DDR2(+LP) Compliance Test Application is a DDR2 (Double Data Rate 2)
test solution that covers electrical, clock and timing parameters of the JEDEC (Joint Electronic
Device Engineering Council) specifications
.
The software helps you in testing all the un-buffered
DDR2 DUTs (devices under test) compliance, with the Keysight 9000, 90000 series, and UXR series
Infiniium digital storage oscilloscope.
There are 2 main categories of test modes:
•
Compliance Tests - These tests are based on the DDR2 JEDEC compliance specifications and are
compared to corresponding compliance test limits.
•
Custom Mode Tests - These tests are not based on any compliance specification. The primary use
of these tests is to perform non-JEDEC specific speed signal testing.
The DDR2(+LP) Compliance Test Application:
•
Lets you select individual or multiple tests to run.
•
Lets you identify the device being tested and its configuration.
•
Shows you how to make oscilloscope connections to the device under test.
•
Automatically checks for proper oscilloscope configuration.
•
Automatically sets up the oscilloscope for each test.
•
Allows you to determine the number of trials for each test, with the new multi trial run capability.
•
Allows you to customize the test limits in the application which determines the pass or/and fail of
each test.
•
Provides detailed information of each test that has been run. The result of maximum twenty five
worst trials can be displayed at any one time.
•
Creates a printable HTML report of the tests that have been run.
The minimum number of probes required for the tests are:
•
Clock tests - 1 probe.
•
Electrical tests - 3 probes.
•
Clock Timing tests - 3 probes.
•
Custom Mode tests - 3 probes.
DDR2 SDRAM electrical, clock and timing test standards and specifications are described in the
JESD79-2E
and
JESD208
document. For more information, please refer to JEDEC web site at
www.jedec.org
.
NOTE
The tests performed by the DDR2(+LP) Compliance Test Application are intended to provide a quick
check of the physical layer performance of the DUT. These testing are not replacement for an
exhaustive test validation plan.
Summary of Contents for D9020DDRC
Page 1: ...Keysight D9020DDRC DDR2 LP Compliance Test Application Methods of Implementation ...
Page 10: ...10 DDR2 LP Compliance Testing Methods of Implementation ...
Page 46: ...2 Preparing to Take Measurements 30 DDR2 LP Compliance Testing Methods of Implementation ...
Page 70: ...3 Measurement Clock Tests 54 DDR2 LP Compliance Testing Methods of Implementation ...
Page 224: ...14 Clock Timing CT Tests 208 DDR2 LP Compliance Testing Methods of Implementation ...
Page 270: ...15 Data Strobe Timing DST Tests 254 DDR2 LP Compliance Testing Methods of Implementation ...