56 - 5
Operation (cont’d)
4
Non-Cushioned Mode
When cushion switch
2
is switched ON, solenoid valve
6
is energised and pilot pressure 39.2 bar (40 kgf/cm
2
)
is fed to port S of cushion valve
5
.
The two cushion spools
Z
are forced into the centre by
pilot pressure so that the unrestricted oilways of the
cushion valve spools are open to the pilot outputs from
dipper remote control valve
8
.
The hot oil from port R returns to the hydraulic oil tank
via port
T
when dipper remote control lever
8
is at
neutral.
When the dipper remote control is operated, pilot
pressure from the lever to port A is fed via the left hand
cushion valve and port C directly to dipper control valve
1
. At the conclusion of lever operation the returning
pilot oil goes straight back to the lever, i.e. there is no
cushioning.
Section E
Hydraulics
9803/6410
Section E
56 - 5
Issue 1
Cushion Valves