33 - 2
Neutral Circuit (cont’d)
Note:
The following description is for that part of the neutral
circuit supplied from pump
P1
. The neutral circuit supplied
from pump
P2
operates in a similar way.
Oil from pump
P1
to the inlet port
PL
passes through the
neutral gallery
A
over each spool
B
and returns to tank via
the foot release valve section
C
.
When no spools are operated a balance of forces acting on
spool
D
causes it to move to the right. This allows a
pressure signal (based on neutral circuit pressure) to be sent
via port
H
to the pump controller, which reduces pump
output to a minimum.
Section E
Hydraulics
9803/6410
Section E
33 - 2
Issue 1
Control Valve