33 - 3
Auxiliary (OPT) Operation
When pilot pressure is applied to port
bl1
by operating the
Auxiliary Pedal, the spool
E
moves to the right, closing off
neutral gallery
F
. Oil from the pump is directed to outlet port
BL2
, by lifting check valve
G
. At the same time, because
neutral gallery
F
is closed, the foot release valve
H
closes
and stops signal pressure
FL
to the pump controller,
enabling the pump to deliver maximum flow.
When pilot pressure is applied to port
al1
the reverse
operation occurs.