![jcb JS130 Service Manual Download Page 140](http://html1.mh-extra.com/html/jcb/js130/js130_service-manual_3610745140.webp)
5 - 1
Section C
Electrics
9803/6410
Section C
5 - 1
Issue 1
Pump Control
Schematic
Current is sent to electromagnetic proportional pressure reducing valve of the pump in each mode to control pump flow rate.
In the H mode, engine RPM is raised and current value is variable between Imax and Imin. This utilises maximum output of the
engine.
The S,L, and F modes have fixed current values.
Current value of each mode
Mode
H
S
L
F
Machine
Imax
Imin
IS
IL
IF
Type
JS130
495 mA
300 mA
305 ± 20 mA
0 + 10 mA
0 + 10 mA
JS160
520 mA
325 mA
330 ± 20 mA
0 + 10 mA
0 + 10 mA