![background image](http://html1.mh-extra.com/html/jcb/js130/js130_service-manual_3610745138.webp)
4 - 13
Engine Auto Warm-up
Time Chart
Conditions for automatic warming up
1
Water temperature is less than 50°C.
2.
Upper Pilot pressure switch is
OFF.
(attachment is not operating.)
3
Lower Pilot pressure switch is
OFF
.
(travel is not operating.)
4
One-touch idle is turned
OFF
.
5
12 seconds after engine start.
6
Throttle dial not moved.
Note:
The automatic warming up sequence will function only
when the above conditions are adhered to.