![background image](http://html1.mh-extra.com/html/jcb/js130/js130_service-manual_3610745192.webp)
9 - 12
Section C
Electrics
9803/6410
Section C
9 - 12
Issue 1
Fault Finding
Fault Diagnosis (continued)
Battery Charging, Problem No 9
Note:
Message does not go out.
Prior Confirmation
Items
1
The
"MODE"
of the mode display is not flashing.
Troubleshoot
Cause
Remedy
Defective WR
wiring between CN2
Repair WR
and CNC
Clean CN2
Bad connection of
connector
CN2 or controller
terminal or
defect
replace
controller.
Replace
Alternator defect
alternator
Repair WR
Breakage of WR
wiring
wiring between CNC
between
and alternator or
CNC and
bad connection of
alternator
alternator spade
or clean
terminal
spade
terminal.
Does hour meter
operate?
YES
YES
YES
NO
NO
NO
Remove CN2 connector and
measure voltage between
female side terminal WR and
ground?
Is it more than 10V?
Remove spade terminal of
alternator R and measure
voltage between female side and
ground.
Is it more than 10V?
Remove CNC connector and
measure voltage between
male side terminal WR and
ground?
Is it more than 10V?
YES
NO
Summary of Contents for JS130
Page 65: ...Section 3 Section 3 9803 6410 Issue 1 9 1 9 1 Routine Maintenance Component Location Diagram...
Page 118: ......
Page 119: ...3 1 Section C Electrics 9803 6410 Section C 3 1 Issue 1 Layout Operator s Cab...
Page 142: ...5 3 Section C Electrics 9803 6410 Section C 5 3 Issue 1 Pump Control FLOW CHART...
Page 207: ......
Page 209: ......
Page 210: ...3 4 Section E Hydraulics 9803 6410 Section E 3 4 Issue 2 Schematics Shuttle Block...
Page 532: ...Contents Page No Technical Data 1 1 i Engine 9803 6410 i Issue 1 Section K Section K...