Remote Control Valve (Services)
Symptom
1
Low secondary pressure.
2
Unstable secondary pressure.
3
High secondary pressure.
Possible cause
a
Primary pressure is low.
b
Spring
14
is damaged.
c
Clearance between the spool
and seating is too large.
d
The handle unit is loose.
a
Sliding parts are sticking.
b
Fluctuations in the tank line
pressure.
c
Air is trapped in the piping.
a
The tank line pressure is too
high.
b
Sliding parts are sticking.
Remedy
Apply the correct primary pressure.
Renew the spring.
Renew the remote control valve
assembly.
Dismantle, reassemble or renew the
handle unit.
Release the sticking part.
Check return line and filter for
blockage.
Operate the valve several times to
remove the air.
Check return line and filter for
blockage.
Release the sticking part.
Summary of Contents for JS130
Page 65: ...Section 3 Section 3 9803 6410 Issue 1 9 1 9 1 Routine Maintenance Component Location Diagram...
Page 118: ......
Page 119: ...3 1 Section C Electrics 9803 6410 Section C 3 1 Issue 1 Layout Operator s Cab...
Page 142: ...5 3 Section C Electrics 9803 6410 Section C 5 3 Issue 1 Pump Control FLOW CHART...
Page 207: ......
Page 209: ......
Page 210: ...3 4 Section E Hydraulics 9803 6410 Section E 3 4 Issue 2 Schematics Shuttle Block...
Page 532: ...Contents Page No Technical Data 1 1 i Engine 9803 6410 i Issue 1 Section K Section K...