Pump Control
Pressure Increasing System (continued)
L Mode
A Even though the one-touch digging force UP switch is pressed, the voltage is not output to the solenoid valve, and a
pressure increase is not obtained.
B Pressure raising is performed in H, S mode when travel pressure switch is ON. A pressure increase is obtained in travel
plus an attachment function.
F Mode
When F mode is set, voltage is output to the solenoid valve regardless of one-touch digging force UP, and results in
pressure raising condition.
Result
1
A pressure increase is obtained when the travel lever is moved (not displayed on the monitor).
2
There is a pressure increase when travel and an attachment function is called for, even though the digging force UP
switch is not pressed.
3
H,S,F mode: pressure increases during an attachment function. However, in H, S mode digging force UP switch must be
pressed. It is displayed on the monitor. In F mode, the pressure will always increase for improvement of lifting work ability.
It is not displayed on the monitor.
Summary of Contents for JS130
Page 65: ...Section 3 Section 3 9803 6410 Issue 1 9 1 9 1 Routine Maintenance Component Location Diagram...
Page 118: ......
Page 119: ...3 1 Section C Electrics 9803 6410 Section C 3 1 Issue 1 Layout Operator s Cab...
Page 142: ...5 3 Section C Electrics 9803 6410 Section C 5 3 Issue 1 Pump Control FLOW CHART...
Page 207: ......
Page 209: ......
Page 210: ...3 4 Section E Hydraulics 9803 6410 Section E 3 4 Issue 2 Schematics Shuttle Block...
Page 532: ...Contents Page No Technical Data 1 1 i Engine 9803 6410 i Issue 1 Section K Section K...