Display Monitor (continued)
Hydraulic Oil Temperature
Circuit Diagram
1
Overheat switch position and the ON signal of the thermostat sensor are OR processed and number 8 is lit.
2
Overheat switch position and the OFF signal of the thermostat sensor are AND processed and number 8 turns off.
3
Number 8 is lit on the condition that numbers 1-7 are lit.
4
When numbers 1-7 are off and the signal for number 8 is transmitted, they light-up in numerical sequence after a 30
second delay.
5
Number 7 is put out on the condition that number 8 is turned out.
6
If the signal to switch off number 7 is transmitted when number 8 is lit, the lights-out signal of the Thermostat sensor
must also occur.
7
When number 8 is lit, 'OVER HEAT' is indicated.