Theory of Operation
2-37
Located behind the Inner Main Cover, the High Voltage Power Supply (HVPS)
provides power to the Bias Charge Roller, Magnetic Roller, Transfer Roller, and
Detack Saw.
LVPS
The Low-Voltage Power Supply (LVPS) generates low voltages (+5 V and +3.3 V for
logic circuits, +5 V for Laser Diodes, and +24 V for motors/clutches) from AC power.
It also contains the Fuser Relay to switch AC power to the Heater Rod of the Fuser.